Need Real Manufacturer
Catalog resellers often cannot support model-level engineering questions.
Factory review
20 datasheet-confirmed CRF-PA standard models from 30W to 200W.
CorelixRF manufactures GaN solid-state RF power amplifier modules across 30–512MHz, 300–1700MHz, 300–2700MHz and 2–6GHz platforms. Standard models support RF testing, communication, SDR signal chain amplification, subsystem integration and OEM / ODM engineering review with datasheets, RF test data and cooling condition support.




The main risk is not only finding a power amplifier supplier. It is confirming the correct frequency family, output power, voltage, current margin, cooling condition and RF chain compatibility before purchase.
Catalog resellers often cannot support model-level engineering questions.
Factory reviewMultiple frequency bands and power levels make comparison slow.
20-model matrix2–6GHz models use higher-voltage ranges, not 28VDC.
VDC by modelCurrent consumption, airflow and duty cycle must be checked early.
Cooling reviewAntenna, load VSWR, cable loss and connector choices affect PA selection.
System matchingStandard models are defined as these 20 CRF-PA datasheet-confirmed platforms. Other frequency ranges, power levels, voltage ranges, connectors, control interfaces, housing formats or mechanical structures should be handled as custom engineering review.
Use filters for fast review. Datasheet opens the simple access popup; Request opens your quote / engineering review popup.
| Model | Frequency | Power | Gain | Flatness / Input VSWR | Supply | Current | Connector / Cooling | Size / Weight | CTA |
|---|---|---|---|---|---|---|---|---|---|
| CRF-PA-30M512M-30W30–512MHz standard platform | 30–512MHz | 30W | 44–46dB | Typical curve available | 28VDC | ≤4A | SMA-F input / N-F output Air Cooling · CW / Saturated |
125×59×21.5mm / ≤0.5kg | |
| CRF-PA-30M512M-50W30–512MHz standard platform | 30–512MHz | 50W | 46–48dB | Typical curve available | 28VDC | ≤9A | SMA-F input / N-F output Air Cooling · CW / Saturated |
125×59×21.5mm / ≤0.5kg | |
| CRF-PA-30M512M-100W30–512MHz standard platform | 30–512MHz | 100W | 49–51dB | Typical curve available | 28VDC | ≤18A | SMA-F input / N-F output Air Cooling · CW / Saturated |
200×158×25mm / ≤1.4kg | |
| CRF-PA-30M512M-150W30–512MHz standard platform | 30–512MHz | 150W | 51–53dB | Typical curve available | 28VDC | ≤20A | SMA-F input / N-F output Air Cooling · CW / Saturated |
200×158×25mm / ≤1.4kg | |
| CRF-PA-30M512M-200W30–512MHz standard platform | 30–512MHz | 200W | 52–54dB | Typical curve available | 28VDC | ≤30A | SMA-F input / N-F output Air Cooling · CW / Saturated |
200×158×25mm / ≤1.4kg | |
| CRF-PA-300M1700M-30W300–1700MHz standard platform | 300–1700MHz | 30W | 44–46dB | Typical curve available | 28VDC | ≤3A | SMA-F input / N-F output Air Cooling · CW / Saturated |
125×59×21.5mm / ≤0.5kg | |
| CRF-PA-300M1700M-50W300–1700MHz standard platform | 300–1700MHz | 50W | 46–48dB | Typical curve available | 28VDC | ≤7A | SMA-F input / N-F output Air Cooling · CW / Saturated |
125×59×21.5mm / ≤0.5kg | |
| CRF-PA-300M1700M-100W300–1700MHz standard platform | 300–1700MHz | 100W | 49–51dB | Typical curve available | 28VDC | ≤14A | SMA-F input / N-F output Air Cooling · CW / Saturated |
200×158×25mm / ≤1.4kg | |
| CRF-PA-300M1700M-150W300–1700MHz standard platform | 300–1700MHz | 150W | 51–53dB | Typical curve available | 28VDC | ≤22A | SMA-F input / N-F output Air Cooling · CW / Saturated |
200×158×25mm / ≤1.4kg | |
| CRF-PA-300M1700M-200W300–1700MHz standard platform | 300–1700MHz | 200W | 52–54dB | Typical curve available | 28VDC | ≤29A | SMA-F input / N-F output Air Cooling · CW / Saturated |
200×158×25mm / ≤1.4kg | |
| CRF-PA-300M2700M-30W300–2700MHz standard platform | 300–2700MHz | 30W | 44–46dB | Flatness ≤1.8dB / Input VSWR ≤1.8:1 | 28VDC | ≤4A | SMA-F input / N-F output Air Cooling · CW / Saturated |
125×59×21.5mm / ≤0.5kg | |
| CRF-PA-300M2700M-50W300–2700MHz standard platform | 300–2700MHz | 50W | 46–48dB | Flatness ≤1.8dB / Input VSWR ≤1.8:1 | 28VDC | ≤9A | SMA-F input / N-F output Air Cooling · CW / Saturated |
125×59×21.5mm / ≤0.5kg | |
| CRF-PA-300M2700M-100W300–2700MHz standard platform | 300–2700MHz | 100W | 49–51dB | Flatness ≤1.5dB / Input VSWR ≤1.5:1 | 28VDC | ≤18A | SMA-F input / N-F output Air Cooling · CW / Saturated |
200×158×25mm / ≤1.4kg | |
| CRF-PA-300M2700M-150W300–2700MHz standard platform | 300–2700MHz | 150W | 51–53dB | Flatness ≤1.5dB / Input VSWR ≤1.5:1 | 28VDC | ≤20A | SMA-F input / N-F output Air Cooling · CW / Saturated |
200×158×25mm / ≤1.4kg | |
| CRF-PA-300M2700M-200W300–2700MHz standard platform | 300–2700MHz | 200W | 52–54dB | Flatness ≤1.8dB / Input VSWR ≤1.8:1 | 28VDC | ≤36A | SMA-F input / N-F output Air Cooling · CW / Saturated |
200×158×25mm / ≤1.4kg | |
| CRF-PA-2G6G-30W2–6GHz standard platform | 2–6GHz | 30W | 44–46dB | Typical curve available | 36–46VDC | ≤4A | SMA-F input / N-F output Air Cooling · CW / Saturated |
125×59×21.5mm / ≤0.5kg | |
| CRF-PA-2G6G-50W2–6GHz standard platform | 2–6GHz | 50W | 46–48dB | Typical curve available | 40–58VDC | ≤12A | SMA-F input / N-F output Air Cooling · CW / Saturated |
200×158×25mm / ≤1.4kg | |
| CRF-PA-2G6G-100W2–6GHz standard platform | 2–6GHz | 100W | 49–51dB | Typical curve available | 41–51VDC | ≤24A | SMA-F input / N-F output Air Cooling · CW / Saturated |
200×158×25mm / ≤1.4kg | |
| CRF-PA-2G6G-150W2–6GHz standard platform | 2–6GHz | 150W | 51–53dB | Typical curve available | 43–58VDC | ≤27A | SMA-F input / N-F output Air Cooling · CW / Saturated |
200×158×25mm / ≤1.4kg | |
| CRF-PA-2G6G-200W2–6GHz standard platform | 2–6GHz | 200W | 52–54dB | Typical curve available | 44–54VDC | ≤36A | SMA-F input / N-F output Air Cooling · CW / Saturated |
200×158×25mm / ≤1.4kg |
Note: 30–512MHz, 300–1700MHz and 300–2700MHz standard platforms use 28VDC. 2–6GHz models use model-specific higher-voltage supply ranges. All rows use SMA-Female RF input, N-Female RF output, Air Cooling and CW / Saturated output type unless a custom review changes the configuration.
Each frequency family includes 30W, 50W, 100W, 150W and 200W standard models. Custom review starts from the closest standard platform.
28VDC models for lower-band RF testing, communication and integration projects.
30W / 50W / 100W / 150W / 200W28VDC platforms for broad RF test and integration coverage across 300–1700MHz.
5 power tiers100W and 150W models provide tighter flatness and input VSWR per datasheets.
≤1.5 optionsHigher-voltage platform with model-specific supply ranges for 2–6GHz systems.
36–58V rangesCurrent consumption and supply voltage must be reviewed by frequency family, not only by wattage. Higher power requires stronger thermal, duty-cycle and RF-chain review.
For lower output requirements, compact test setups and early-stage system evaluation.
Common for evaluation systems and moderate power integration where current margin matters.
A frequent starting point for high-power RF test and communication integration projects.
Requires careful review of current, airflow, load condition and duty cycle.
Needs stronger thermal review, supply margin and antenna / load VSWR confirmation.
Engineering buyers often need more than a model name. CorelixRF can support datasheets, typical performance curves, RF test records and project documentation based on model and order scope.




Model-level output power can be reviewed with measured data and test references.
Gain reference and frequency response data help buyers compare standard models.
Load condition and input / output matching should be checked before integration.
Datasheets, test reports, packing files and OEM documentation can be prepared by project scope.
The uploaded standard model datasheets list Air Cooling. Airflow, current margin, chassis layout and duty cycle should still be reviewed before final model confirmation.
Confirm airflow, heat path and installation environment before system assembly.
Current consumption changes by frequency family and power tier, especially 2–6GHz.
30W/50W models may use compact format; higher power models typically need larger module space.
Amplifier output should be reviewed with cable loss, antenna power handling and load condition.
These standard platforms support RF testing, SDR source amplification, broadband subsystem integration and controlled RF engineering platforms.
Amplifier platforms for test benches, measurement setups and validation chains.
Boost RF output from SDR or signal source modules into higher-power RF chains.
Standard PA modules can serve as starting points for OEM hardware platforms.
Engineering-side RF amplifier support for controlled telemetry and link platforms.
RF hardware integration support for specialized engineering and validation systems.
These answers help buyers prepare a more accurate RF amplifier RFQ and avoid selecting the wrong model.
CorelixRF standard RF power amplifier models include 20 CRF-PA models across 30–512MHz, 300–1700MHz, 300–2700MHz and 2–6GHz. Each frequency family includes 30W, 50W, 100W, 150W and 200W tiers.
No. The 30–512MHz, 300–1700MHz and 300–2700MHz standard platforms use 28VDC. The 2–6GHz models use model-specific higher-voltage ranges from 36–46VDC to 44–54VDC depending on power level.
Yes. Datasheets, typical performance curves, gain reference, input match / SWR references and project documentation can be supplied depending on model and order scope.
Yes. Requests outside the 20 standard CRF-PA models can be reviewed as custom engineering projects, including frequency range, power level, voltage range, connector, control interface, housing and mechanical format.
Please provide frequency range, output power, CW or pulse condition, supply voltage, connector preference, cooling condition, load VSWR, quantity and documentation requirements.
Tell us your frequency range, output power, CW or pulse condition, supply voltage, connector preference, load VSWR, cooling condition, quantity and documentation requirement. CorelixRF can recommend a standard PA model or review a custom direction.