Frequency-specific designs
Separate microwave and mmWave operating windows, including broadband and application-focused configurations. For a configuration-specific engineering example, see Planning a 50–65 GHz 120 W mmWave Amplifier Installation.
CORELIXRF · FACTORY-DIRECT RF AMPLIFIERS
Frequency-specific platforms. Coaxial and waveguide interfaces. Built around your RF system.
CorelixRF supplies microwave and mmWave amplifier configurations for RF testing, communication links and OEM integration—with engineering, assembly and test support.

SERIES CHARACTERISTICS
Choose the operating window and hardware interface that fit your system. Electrical and mechanical details follow the selected configuration.
Separate microwave and mmWave operating windows, including broadband and application-focused configurations. For a configuration-specific engineering example, see Planning a 50–65 GHz 120 W mmWave Amplifier Installation.
Compare rated, saturated, linear or pulsed output with its stated Min / Typ value and operating condition.
Configuration options include precision coaxial connectors and WR22, WR19, WR15 or WR10 waveguide interfaces. For a configuration-specific engineering example, see How to Specify a 36–50 GHz CRF-PA-36G50G mmWave Amplifier.
Review compact or rack formats, control interfaces, power supply, air cooling and model-specific water cooling.

Compare documented frequency and output combinations. Request the matching datasheet and mechanical drawing for your configuration.
REPRESENTATIVE CONFIGURATIONS
Start with these six configurations, or browse the full reference list below. Each frequency window belongs to a separate configuration.
Datasheet imageCRF-PA-18G46G-5W
GaN technology; air cooling. Request the matching datasheet for the selected configuration.
Image: datasheet image. Confirm the final mechanical configuration with the matching drawing.
Enclosure illustrationCRF-PA-36G50G-30W
Review operating mode, mechanical drawing and final supply configuration.
Image: enclosure illustration. Confirm the final mechanical configuration with the matching drawing.
Enclosure illustrationCRF-PA-40G54G-200W
Review operating mode, mechanical drawing and final supply configuration.
Image: enclosure illustration. Confirm the final mechanical configuration with the matching drawing.
Edited enclosure referenceCRF-PA-40G67G-2W
Review operating mode, mechanical drawing and final supply configuration.
Image: edited enclosure reference. Confirm the final mechanical configuration with the matching drawing.
Enclosure illustrationCRF-PA-50G75G-5W
Review operating mode, mechanical drawing and final supply configuration.
Image: enclosure illustration. Confirm the final mechanical configuration with the matching drawing.
Datasheet imageCRF-PA-75G110G-1W
Review operating mode, mechanical drawing and final supply configuration.
Image: datasheet image. Confirm the final mechanical configuration with the matching drawing.
Min / Typ retain their datasheet definitions. Product photos and labelled enclosure illustrations show appearance references; the matching drawing defines the final mechanical configuration.
SIDE-BY-SIDE CONFIGURATION COMPARISON
Compare the six representative configurations by frequency, stated output and RF interface. Request the matching datasheet to review the configuration for your design or quotation.
| Reference / Frequency | Output Definition | RF Interfaces | Review Note | Next Step |
|---|---|---|---|---|
| CRF-PA-18G46G-5W18–46 GHz | Typ 5 W Rated Output Power | Input: 2.4 mm-F / Output: 2.4 mm-F | GaN technology; air cooling. Request the matching datasheet for the selected configuration. | Enquire |
| CRF-PA-36G50G-30W36–50 GHz | Min 30 W Rated Output Power | Input: 1.85 mm-F / Output: WR22 | Confirm operating mode, mechanical details and final configuration. | Enquire |
| CRF-PA-40G54G-200W40–54 GHz | Min 200 W Rated Output Power | Input: 1.85 mm-F / Output: WR19 | Confirm operating mode, mechanical details and final configuration. | Enquire |
| CRF-PA-40G67G-2W40–67 GHz | Min 2 W Rated Output Power | Input: 1.85 mm-F / Output: 1.85 mm-F | Confirm operating mode, mechanical details and final configuration. | Enquire |
| CRF-PA-50G75G-5W50–75 GHz | Min 5 W Rated Output Power | Input: WR15 / Output: WR15 | Confirm operating mode, mechanical details and final configuration. | Enquire |
| CRF-PA-75G110G-1W75–110 GHz | Typ 1 W Rated Output Power | Input: WR10 / Output: WR10 | Confirm operating mode, mechanical details and final configuration. | Enquire |
Min / Typ and Rated Output Power retain the original definitions. Confirm CW or pulse operation, cooling and mechanical details in the matching configuration datasheet.
62 configurations
GaN technology; air cooling. Request the matching datasheet for the selected configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Gain Min 50 dB; gain flatness Max ±10 dB; RS485 / LAN control; air cooling.
Gain Min 49 dB; gain flatness Max ±2 dB; P1dB output Min 50 W; RS485 / LAN control; air cooling.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Gain Min 27 dB; gain flatness Max ±8 dB; RS485 control; air cooling.
Gain Min 26 dB; gain flatness Max ±10 dB; noise floor Typ −40 dBm/MHz; RS485 / LAN control; air cooling. For a configuration-specific engineering example, see 65–75 GHz V-Band mmWave Power Amplifier Selection Guide.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Use the documented 47.2–51.4 GHz range and Min 53 dBm output. The 200 W model name is a reference label. DC and AC enclosure dimensions differ; select the supply configuration first.
Saturated output: Min 400 W. Linear output: Min 100 W. Select the output condition for your application.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Water Cooling; AC 380 V ±10%, 50/60 Hz. Min 500 W pulse / Min 250 W CW. Operating conditions follow the project-approved datasheet.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Review operating mode, mechanical drawing and final supply configuration.
Try another model, interface or frequency group, or send us your requirement.
Discuss a custom configuration ↗Output values are the electrical table’s Rated Output Power unless a different definition is shown. No CW or pulse capability is inferred from a model name. Final specifications follow the project-approved datasheet.

CUSTOM CONFIGURATION & OEM SUPPORT
When a reference does not match your operating window or installation, our team can review the configuration with you.
Discuss your configurationAPPLICATION DIRECTIONS
Use the application to define the required signal, output and integration conditions for your selected configuration.
Component characterization and laboratory RF benches requiring a defined operating window, input drive and measurement plan.
Discuss a test setup ↗RF chain evaluation with signal bandwidth, modulation, linear output and back-off requirements matched to the project.
Discuss a link requirement ↗Equipment integration around the RF path, supply, cooling, mounting space, control protocol and acceptance requirements.
Discuss an OEM project ↗ENGINEERING & MANUFACTURING SUPPORT
Mechanical design, module assembly and RF bench review support the path from configuration discussion to production.

Enclosure, RF connections and assembly details.

Agree the measurements and acceptance limits for your configuration.

Request the matching datasheet, drawing and available test records.
QUESTIONS BEFORE YOU SELECT
Keep the configuration, operating conditions and integration documents aligned.
Start with the full operating window, signal bandwidth and required output definition. Then review input drive, RF interfaces, operating mode, supply and cooling against the selected reference. Use the project-approved datasheet and mechanical drawing for integration. For a configuration-specific engineering example, see 75–110 GHz W-Band Amplifiers: Comparing the 1 W to 4 W Configurations.
The references include separate 18–46, 36–50, 40–54, 40–67, 50–65, 50–67, 50–75, 65–75, 75–110, 75–81, 81–86, 90–98 and 92–96 GHz configurations, plus 47–51.4 GHz references. The 200 W-labelled reference in that last group is documented at 47.2–51.4 GHz. Each range belongs to its own configuration and is reviewed individually.
Microwave and mmWave product ranges can overlap in supplier catalogs. Select by the exact operating window and documented configuration. The CorelixRF microwave amplifier page covers broader microwave selection; this page focuses on the listed higher-frequency references, RF interfaces and integration conditions. The engineering guide Coaxial vs Waveguide Interfaces for Microwave and mmWave Amplifiers develops the selection and interface questions in more detail.
Use the selected datasheet and frequency-dependent test information to determine output across the requested band. A broadband RF amplifier range label does not establish identical output, gain or linearity at every frequency. Retain Min and Typ definitions and the stated test conditions.
These labels describe different output conditions and must be read as defined in the selected datasheet. For example, the 47–51.4 GHz / 400 W reference electrical table lists saturated output Min 400 W and linear output Min 100 W. Select the output condition that matches your application. For a configuration-specific engineering example, see Evaluating a 47–51.4 GHz 200 W Amplifier for a V-Band Test System.
The 18–46 GHz / 5 W and the five 36–50 GHz reference documents explicitly identify GaN technology. These support a GaN RF power amplifier configuration review. The technology of other references must be confirmed individually; this is not an all-GaN claim for the page.
START WITH YOUR OPERATING REQUIREMENT
Share the output condition, RF interface, supply, cooling and installation needs.