High Power RF Output
Compare 300 W, 500 W and 1500 W model classes using the rated output definition and pulse conditions in each datasheet.
Discuss Output Requirements
Explore CorelixRF pulsed RF amplifier options for radar and RF test requirements. Compare L-band and S-band models in 300 W, 500 W and 1500 W power classes, then review each model’s rated output, pulse width, duty cycle, control interface and cooling requirements.
Custom configurations are assessed against your project specifications. Request the selected model’s datasheet and confirm output conditions, supply, enclosure and acceptance requirements before integration.
Choosing a high power RF amplifier for pulsed operation requires more than a wattage comparison. Review the operating band, rated output, pulse width and duty cycle together. The listed models use GaN technology; select a solid state power amplifier against the required pulse conditions, cooling arrangement and system interfaces. The engineering guide Specifying a 25 kW S-Band Pulsed Amplifier: Pulse Profile and Output Evidence develops the selection and interface questions in more detail.
Compare 300 W, 500 W and 1500 W model classes using the rated output definition and pulse conditions in each datasheet.
Discuss Output RequirementsEach of the four listed datasheets identifies GaN technology. Review the solid state RF amplifier configuration against your signal, cooling and integration requirements.
Request Model DataReview pulse width, repetition rate, duty cycle and timing together. Listed ranges do not make every possible combination valid.
Review Pulse ConditionsConfirm supply, enclosure, RF connectors and control logic. Optional monitoring and GPIB functions require configuration review.
Discuss OEM IntegrationSelect a pulsed RF power amplifier using the complete operating band, output definition, pulse width, repetition rate and duty cycle together. Include input drive, load, timing and cooling conditions when comparing models. The engineering guide CW or Pulsed RF Amplification: Define the Drive and Bias Cases develops the selection and interface questions in more detail.
Match the full required band to one model. The L-band and S-band options are separate configurations, not continuous 1.0–3.2 GHz coverage.
Keep rated output, peak output, average output and P1 specifications distinct. Use the selected datasheet’s definitions and agreed test conditions.
Confirm pulse width, repetition rate and duty cycle as a valid combination. Do not combine one model’s power with another model’s timing limits.
Identify the control interface and pulse control interface separately. Confirm signal levels and integration requirements before connecting equipment.
Use the project-approved electrical configuration to select the supply voltage, frequency and power capacity.
All four references specify air cooling. Plan airflow and installation space using the project-approved mechanical drawing.
Compare the separate frequency and power configurations below. L-band and S-band labels help with selection; use the exact model frequency range and pulse conditions to define your requirement.
Reference Outline
CRF-PA-1000M2000M-1500W: rated output Min 1500 W, pulse width Typ 1–50 μs and duty cycle Typ 5%. Air cooling; RS485 / LAN control.
View Model Details
1.2–1.4 GHz / 500 W Outline
CRF-PA-1200M1400M-500W: rated output Min 500 W, pulse width Typ 50 μs and duty cycle Typ 10%; 19-inch 3U reference.
View Model Details
CRF-PA-2700M3100M-500W · Outline
2700–3100 MHz / Min 500 W and 2900–3200 MHz / Min 300 W are separate S-band amplifier models. Neither entry establishes 500 W across 2.7–3.2 GHz.
View Model Details| Model / Frequency | Rated Output (Min) | Gain (Min) | Pulse Conditions (Typ) | Control Interfaces | Integration Data | Model Data |
|---|---|---|---|---|---|---|
| CRF-PA-1000M2000M-1500W · 1000–2000 MHz | 1500 W | 62 dB | 1–50 μs pulse width; 5% duty cycle | RS485 / LAN | Air cooling | Request Data |
| CRF-PA-1200M1400M-500W · 1200–1400 MHz | 500 W | 57 dB | 50 μs pulse width; 10% duty cycle | RS485 / LAN | AC 220V ±10%, 50/60 Hz; 19-inch 3U / 18 kg | Request Data |
| CRF-PA-2700M3100M-500W · 2700–3100 MHz | 500 W | 57 dB | 50 μs pulse width; 10% duty cycle | RS485 / LAN | AC 220V ±10%, 50/60 Hz; 19-inch 3U / 18 kg | Request Data |
| CRF-PA-2900M3200M-300W · 2900–3200 MHz | 300 W | 50 dB | 1–15 μs pulse width; 1–25% duty cycle; 1–20 kHz repetition rate | Control: RS422; pulse control: RS485-3.3V | 24 VDC / 20 kg | Request Data |
Min and Typ retain the datasheet column definitions. Confirm pulse width, repetition rate and duty cycle together; range endpoints are not freely interchangeable. On small screens, scroll the table horizontally.
Use these four model references to compare a pulsed RF amplifier for your frequency and output requirements. Request the selected datasheet and confirm the full electrical, pulse and mechanical configuration before ordering.
1500W PlatformL-band high power pulsed RF amplifier reference with rated output Min 1500 W at the stated pulse conditions. Confirm the approved supply and enclosure configuration before integration.
500W PlatformL-band pulsed RF amplifier reference for 1200–1400 MHz with rated output Min 500 W, pulse width Typ 50 μs and duty cycle Typ 10%. Review the 3U air-cooled configuration for your system.
S-Band PlatformS-band amplifier reference for 2700–3100 MHz with rated output Min 500 W, pulse width Typ 50 μs and duty cycle Typ 10%. Confirm waveform and RF interfaces for the intended test or integration requirement.
Pulse ControlS-band pulsed RF amplifier reference for 2900–3200 MHz. Rated output Min 300 W and P1 Output Power Min 250 W are separate specifications. Confirm a valid combination of pulse width, repetition rate and duty cycle. The engineering guide Pulsed RF Amplifier Selection: Check Compatible Pulse Conditions develops the selection and interface questions in more detail.
Agree the relevant test conditions and documentation before production or shipment. Available records depend on the selected model, configuration and project scope.
Review rated output, gain, pulse timing, thermal conditions and control behavior with the selected configuration. Request applicable model data and agree acceptance criteria for your project.
Review pulse width, duty cycle, pulse frequency and timing behavior before configuration.
Check rated output power, gain, harmonics, spurious and impedance condition under defined test conditions.
Confirm air cooling structure, cabinet size, airflow path and thermal margin before production.
Review RS485, LAN, RS422, pulse control logic or optional GPIB control according to project needs.
Datasheet, mechanical reference, connector reference and test data can be supplied where applicable. Available documentation depends on the model, test conditions and customer project requirement.
Submit non-standard pulsed RF power amplifier requirements for project assessment. Frequency, output, pulse timing, monitoring, controls, cooling and enclosure options are reviewed together before a configuration is proposed.
Optional functions can include forward / reverse power monitoring, input power detection, GPIB control interface and project-based mechanical or interface adaptation.
Custom frequency subsets, rated output power and gain targets can be reviewed for project-specific requirements.
Pulse width, duty cycle, pulse frequency, rise/fall time and pulse droop can be reviewed according to thermal and RF performance targets.
RS485, LAN, RS422, pulse control interface and optional GPIB control can be reviewed.
Forward/reverse power monitoring, input power detection and protection logic can be discussed for system integration.
Review enclosure format, cooling, airflow and connector layout against the project-approved mechanical drawing.
Review RF connector, power supply, control logic, enclosure format and installation reference for your OEM system.
Send frequency, power, pulse width, duty cycle, pulse frequency, interface and integration requirements for engineering review.
For a radar amplifier or radar power amplifier requirement, provide the operating band, waveform, required output, pulse width, repetition rate and duty cycle. CorelixRF reviews the proposed configuration against those conditions, together with timing, control, cooling and integration requirements.
Review radar-related waveforms, pulse timing, output requirements and control interfaces against a specific amplifier configuration.
Define the RF signal, input drive, test load and measurement conditions for pulsed amplifier evaluation.
Match the operating band, waveform and required output to the test chain. Frequency overlap alone does not establish signal compatibility.
Assess the selected model against the test band, modulation, load and pulse conditions. Review EMC amplifier options for broader test requirements.
Compare the exact listed frequency ranges and model-specific pulse data when defining a band-specific RF chain.
Confirm the supply, cooling, RF connectors, control logic and mechanical arrangement for the complete subsystem.
Provide your operating conditions, compare the proposed model and resolve open electrical or mechanical details before agreeing the quotation, validation scope and delivery documentation.
Provide frequency, output definition, waveform, pulse timing, supply, cooling and quantity.
Review the closest listed model or the feasibility of a custom configuration.
Match supply, enclosure and interfaces to the system and agree the required pulse operating conditions.
Agree the configuration, required records, acceptance criteria and quotation scope.
Confirm the approved datasheet, mechanical information and applicable test records.
Answers to common questions about pulsed RF selection, GaN technology, radar requirements, model specifications and quotations.
A pulsed RF amplifier amplifies RF signals under defined pulse conditions. Select it using the operating band, output definition, pulse width, repetition rate, duty cycle, input drive and load requirements.
Compare the complete operating band and output requirement first, then check pulse timing, supply, cooling, interfaces and the load. A solid state high power amplifier must meet the required operating conditions; a higher wattage label alone does not establish suitability.
No. These terms describe different output definitions or operating conditions. The comparison table preserves Rated Output Power and Min as listed in the source datasheets. Do not treat these figures as average or CW output. The 300 W model separately lists P1 Output Power Min 250 W.
The four listed model datasheets identify GaN technology. When selecting a GaN RF power amplifier or solid state RF amplifier, review the specific output, pulse, cooling and interface data rather than assuming identical performance across the range.
Yes. Submit the operating band, waveform, output target, pulse width, repetition rate, duty cycle and timing requirements. A radar power amplifier configuration must be assessed against those inputs and the system interfaces; the model listing alone does not establish suitability for every radar system.
The S-band amplifier options are CRF-PA-2700M3100M-500W at 2700–3100 MHz and CRF-PA-2900M3200M-300W at 2900–3200 MHz. Their rated outputs are Min 500 W and Min 300 W respectively, with different pulse conditions. They are separate models.
Custom pulse conditions can be submitted for engineering assessment. Pulse width, repetition rate and duty cycle must be confirmed together with RF performance and thermal requirements. The listed ranges do not mean every combination is supported.
Do not assume CW capability from a pulsed rating. Continuous operation requires separate confirmation of the selected configuration, output, supply and thermal conditions. Provide the intended operating mode when requesting model data.
RF amplifier price depends on the selected model, pulse conditions, interfaces, cooling, enclosure, quantity and agreed validation requirements. Send the required operating conditions and project scope to request a configuration-specific quotation.
Use the datasheet or quote button on the relevant model card. Include frequency, required output, pulse width, repetition rate, duty cycle, supply, cooling, interfaces and quantity. Final specifications are defined by the project-approved datasheet and mechanical drawing.
Request a quotation for a listed pulsed RF amplifier or submit a custom requirement. Share frequency, required output, pulse width, repetition rate, duty cycle, interfaces, supply, cooling and quantity. Use the project-approved specifications for integration.