CorelixRF supplies directional antennas for communication, RF testing and system integration. Start with the antenna type, then compare frequency, beamwidth, gain and installation requirements.

DIRECTIONAL ANTENNA FORMATS
Original page illustration of horn and panel antenna formats
Choose the type.
Define the coverage.

8 panel references · 2 horn references.
Illustrated formats are representative; confirm the selected model and interface.

PANEL & HORN REFERENCESMODEL-SPECIFIC RF PARAMETERSCUSTOMIZATION & INTEGRATION REVIEW

CHOOSE A DIRECTIONAL ANTENNA TYPE

Start with the coverage.
Then choose the format.

Panel and horn antennas offer different physical formats and documented operating bands. Review the required direction, coverage angle and mounting space before choosing a reference.

01 / PANEL ANTENNAS · 8 REFERENCES

Defined bands.
Installation-led selection.

Compare vertically polarized panel configurations for fixed installations. Use the horizontal and vertical beamwidth together to assess the area you need to cover. For a configuration-specific engineering example, see How to Deploy a 5150-5250 MHz Panel Antenna in an RF System.

  • Separate sub-1 GHz, L-band and higher-frequency options
  • Wall or pole mounting, depending on the reference
  • Model-specific gain, connector and power conditions
Compare panel configurations ↓
02 / HORN ANTENNAS · 2 REFERENCES

Broader bands.
Directional RF evaluation.

Review a horn configuration when the project calls for a wider operating range. Check its frequency-dependent gain and H/E-plane pattern alongside the available installation space. For the measurement and evidence questions behind this review, see Gain Horn Mounts: Mechanical Datums and Measurement Repeatability.

  • Two separate broadband frequency windows
  • Different connectors, dimensions and mounting arrangements
  • Band-specific performance and power review
Compare horn configurations ↓
01Required frequencies
02Direction & coverage angle
03Mounting & polarization
04Power & RF interface

DIRECTIONAL ANTENNA CONFIGURATIONS

Find a reference for
your operating band.

Start with these representative configurations, then compare all ten references below. Values retain the definitions and qualifications in the corresponding datasheets.

Datasheet sample photograph · final configuration to confirm; Panel antenna format
Datasheet sample photograph · final configuration to confirm

PANEL REFERENCE

868–915 MHz

CRF-DA-868-915MHz-11dBi

Gain
11 dBiDatasheet stated
RF interface
N-K
Power handling
Confirm rating
Datasheet sample photograph · final configuration to confirm; Panel antenna format
Datasheet sample photograph · final configuration to confirm

PANEL REFERENCE

1430–1444 MHz

CRF-DA-1430-1444MHz-14dBi

Gain
14 ±1 dBiDatasheet stated
RF interface
N-Female
Power handling
200 W max.*
Original horn illustration · confirm model drawing; Horn antenna format
Original horn illustration · confirm model drawing

HORN REFERENCE

400–2700 MHz

CRF-DA-400M2700M-6-12dBi

Gain
6–12 dBiDatasheet Min–Max
RF interface
SMA-K
Power handling
100 W max.*
Original horn illustration · confirm model drawing; Horn antenna format
Original horn illustration · confirm model drawing

HORN REFERENCE

2000–6000 MHz

CRF-DA-2000M6000M-13.16-19.07dBi

Gain
13.16–19.07 dBiDatasheet Min–Max
RF interface
N-J
Power handling
Confirm rating

COMPLETE CONFIGURATION COMPARISON

Compare panel & horn antennas.

All 10 references · vertical polarization · 50 Ω
Open a row for beamwidth, interface, mounting and conditions.

10 of 10 references

Source values · power conditions remain configuration-specific

PANEL REFERENCECRF-DA-868-915MHz-11dBiFrequency868–915 MHzGain11 dBiDatasheet statedPower handlingConfirm ratingBeamwidth180° H / 30° VDatasheet stated*Details
Frequency
868–915 MHz
Gain
11 dBi · Datasheet stated
Half-power beamwidth
180° H / 30° V
Polarization / impedance
Vertical / 50 Ω
Power handling
100–150 W stated as maximum input power; applicable rating and conditions require confirmation.
VSWR
<1.5 · datasheet
RF connector
N-K
Dimensions
600 × 160 × 60 mm
Mounting
Wall or pole mount

Before final selection

  • Maximum input power is not an unconditional CW or peak rating. Confirm operating frequency, duty cycle and installation conditions before amplifier matching.
  • Gain and beamwidth are source values. Request patterns at your frequencies with the measurement plane and configuration identified.
  • The datasheet lists a 100–150 W maximum-input-power range. Confirm the applicable value for the selected configuration.
Request matching datasheet ↗
PANEL REFERENCECRF-DA-1430-1444MHz-14dBiFrequency1430–1444 MHzGain14 ±1 dBiDatasheet statedPower handling200 W max.*Beamwidth70 ±10° H / 20 ±5° VDatasheet stated*Details
Frequency
1430–1444 MHz
Gain
14 ±1 dBi · Datasheet stated
Half-power beamwidth
70 ±10° H / 20 ±5° V
Polarization / impedance
Vertical / 50 Ω
Power handling
200 W maximum input power stated in the electrical table; operating conditions to confirm.
VSWR
≤1.8 · datasheet
RF connector
N-Female
Dimensions
900 × 160 × 80 mm
Mounting
Pole mount; Ø35–90 mm hardware; 0–15° mechanical tilt

Before final selection

  • Maximum input power is not an unconditional CW or peak rating. Confirm operating frequency, duty cycle and installation conditions before amplifier matching.
  • Gain and beamwidth are source values. Request patterns at your frequencies with the measurement plane and configuration identified.
  • The available pattern figures are reused across several panel references and lack a measurement frequency. Request matching H/V records before final coverage approval.
Request matching datasheet ↗
PANEL REFERENCECRF-DA-2400-2500MHz-14dBiFrequency2400–2500 MHzGain14 dBiDatasheet statedPower handlingConfirm ratingBeamwidth180° H / 30° VDatasheet stated*Details
Frequency
2400–2500 MHz
Gain
14 dBi · Datasheet stated
Half-power beamwidth
180° H / 30° V
Polarization / impedance
Vertical / 50 Ω
Power handling
100–150 W stated as maximum input power; applicable rating and conditions require confirmation.
VSWR
<1.5 · datasheet
RF connector
N-K
Dimensions
420 × 150 × 40 mm
Mounting
Wall or pole mount

Before final selection

  • Maximum input power is not an unconditional CW or peak rating. Confirm operating frequency, duty cycle and installation conditions before amplifier matching.
  • Gain and beamwidth are source values. Request patterns at your frequencies with the measurement plane and configuration identified.
  • The datasheet lists a 100–150 W maximum-input-power range. Confirm the applicable value for the selected configuration.
Request matching datasheet ↗
PANEL REFERENCECRF-DA-2400-2500MHz-15dBiFrequency2400–2500 MHzGain15 ±1 dBiDatasheet statedPower handling200 W max.*Beamwidth90 ±10° H / 20 ±5° VDatasheet stated*Details
Frequency
2400–2500 MHz
Gain
15 ±1 dBi · Datasheet stated
Half-power beamwidth
90 ±10° H / 20 ±5° V
Polarization / impedance
Vertical / 50 Ω
Power handling
200 W maximum input power stated in the electrical table; operating conditions to confirm.
VSWR
≤1.5 · datasheet
RF connector
N-Female
Dimensions
600 × 160 × 80 mm
Mounting
Pole mount; Ø35–90 mm hardware; 0–15° mechanical tilt

Before final selection

  • Maximum input power is not an unconditional CW or peak rating. Confirm operating frequency, duty cycle and installation conditions before amplifier matching.
  • Gain and beamwidth are source values. Request patterns at your frequencies with the measurement plane and configuration identified.
  • The available pattern figures are reused across several panel references and lack a measurement frequency. Request matching H/V records before final coverage approval.
Request matching datasheet ↗
PANEL REFERENCECRF-DA-5150-5250MHz-14dBiFrequency5150–5250 MHzGain14 dBiDatasheet statedPower handlingConfirm ratingBeamwidth180° H / 30° VDatasheet stated*Details
Frequency
5150–5250 MHz
Gain
14 dBi · Datasheet stated
Half-power beamwidth
180° H / 30° V
Polarization / impedance
Vertical / 50 Ω
Power handling
100–150 W stated as maximum input power; applicable rating and conditions require confirmation.
VSWR
<1.5 · datasheet
RF connector
N-K
Dimensions
420 × 150 × 40 mm
Mounting
Wall or pole mount

Before final selection

  • Maximum input power is not an unconditional CW or peak rating. Confirm operating frequency, duty cycle and installation conditions before amplifier matching.
  • Gain and beamwidth are source values. Request patterns at your frequencies with the measurement plane and configuration identified.
  • The datasheet lists a 100–150 W maximum-input-power range. Confirm the applicable value for the selected configuration.
Request matching datasheet ↗
PANEL REFERENCECRF-DA-5150-5250MHz-16dBiFrequency5150–5250 MHzGain16 ±1 dBiDatasheet statedPower handling200 W max.*Beamwidth70 ±10° H / 17 ±3° VDatasheet stated*Details
Frequency
5150–5250 MHz
Gain
16 ±1 dBi · Datasheet stated
Half-power beamwidth
70 ±10° H / 17 ±3° V
Polarization / impedance
Vertical / 50 Ω
Power handling
200 W maximum input power stated in the electrical table; operating conditions to confirm.
VSWR
≤1.5 · datasheet
RF connector
N-Female
Dimensions
600 × 160 × 80 mm
Mounting
Pole mount; Ø35–90 mm hardware; 0–15° mechanical tilt

Before final selection

  • Maximum input power is not an unconditional CW or peak rating. Confirm operating frequency, duty cycle and installation conditions before amplifier matching.
  • Gain and beamwidth are source values. Request patterns at your frequencies with the measurement plane and configuration identified.
  • The available pattern figures are reused across several panel references and lack a measurement frequency. Request matching H/V records before final coverage approval.
Request matching datasheet ↗
PANEL REFERENCECRF-DA-5725-5850MHz-14dBiFrequency5725–5850 MHzGain14 dBiDatasheet statedPower handlingConfirm ratingBeamwidth180° H / 30° VDatasheet stated*Details
Frequency
5725–5850 MHz
Gain
14 dBi · Datasheet stated
Half-power beamwidth
180° H / 30° V
Polarization / impedance
Vertical / 50 Ω
Power handling
100–150 W stated as maximum input power; applicable rating and conditions require confirmation.
VSWR
<1.5 · datasheet
RF connector
N-K
Dimensions
420 × 150 × 40 mm
Mounting
Wall or pole mount

Before final selection

  • Maximum input power is not an unconditional CW or peak rating. Confirm operating frequency, duty cycle and installation conditions before amplifier matching.
  • Gain and beamwidth are source values. Request patterns at your frequencies with the measurement plane and configuration identified.
  • The datasheet lists a 100–150 W maximum-input-power range. Confirm the applicable value for the selected configuration.
Request matching datasheet ↗
PANEL REFERENCECRF-DA-5725-5850MHz-16dBiFrequency5725–5850 MHzGain16 ±1 dBiDatasheet statedPower handling200 W max.*Beamwidth70 ±10° H / 17 ±3° VDatasheet stated*Details
Frequency
5725–5850 MHz
Gain
16 ±1 dBi · Datasheet stated
Half-power beamwidth
70 ±10° H / 17 ±3° V
Polarization / impedance
Vertical / 50 Ω
Power handling
200 W maximum input power stated in the electrical table; operating conditions to confirm.
VSWR
≤1.5 · datasheet
RF connector
N-Female
Dimensions
600 × 160 × 80 mm
Mounting
Pole mount; Ø35–90 mm hardware; 0–15° mechanical tilt

Before final selection

  • Maximum input power is not an unconditional CW or peak rating. Confirm operating frequency, duty cycle and installation conditions before amplifier matching.
  • Gain and beamwidth are source values. Request patterns at your frequencies with the measurement plane and configuration identified.
  • The available pattern figures are reused across several panel references and lack a measurement frequency. Request matching H/V records before final coverage approval.
Request matching datasheet ↗
HORN REFERENCECRF-DA-400M2700M-6-12dBiFrequency400–2700 MHzVSWR confirmation requiredGain6–12 dBiDatasheet Min–MaxPower handling100 W max.*Beamwidth76° H-plane / 99° E-planeDatasheet stated*Details
Frequency
400–2700 MHz
Gain
6–12 dBi · Datasheet Min–Max
Half-power beamwidth
76° H-plane / 99° E-plane
Polarization / impedance
Vertical / 50 Ω
Power handling
100 W maximum input power stated in the electrical table; operating conditions to confirm.
VSWR
Band-specific confirmation
RF connector
SMA-K
Dimensions
445 × 370 × 480 mm
Mounting
Standard horn mounting structure

Before final selection

  • Maximum input power is not an unconditional CW or peak rating. Confirm operating frequency, duty cycle and installation conditions before amplifier matching.
  • Gain and beamwidth are source values. Request patterns at your frequencies with the measurement plane and configuration identified.
  • Confirm the final ordering code, sample appearance and installation drawing; the source sample-page label differs from the electrical-page reference.
  • The table states VSWR <2.0, but the supplied sweep starts at 800 MHz and exceeds 2.0 at some points. Confirm the limit and obtain a matching sweep for your required band, including 400–800 MHz where applicable.
  • Some supplied pattern captions and frequency labels do not agree, and some plots are repeated. Request corrected records identified by frequency and measurement plane.
Request matching datasheet ↗
HORN REFERENCECRF-DA-2000M6000M-13.16-19.07dBiFrequency2000–6000 MHzGain13.16–19.07 dBiDatasheet Min–MaxPower handlingConfirm ratingBeamwidth75.44° H-plane / 60.18° E-planeDatasheet stated*Details
Frequency
2000–6000 MHz
Gain
13.16–19.07 dBi · Datasheet Min–Max
Half-power beamwidth
75.44° H-plane / 60.18° E-plane
Polarization / impedance
Vertical / 50 Ω
Power handling
Electrical table: 100 W maximum. Header: 50–100 W. Confirm the applicable input-power rating and conditions.
VSWR
<2.0 · datasheet
RF connector
N-J
Dimensions
450 × 230 × 415 mm
Mounting
Optional mounting styles; confirm drawing

Before final selection

  • Maximum input power is not an unconditional CW or peak rating. Confirm operating frequency, duty cycle and installation conditions before amplifier matching.
  • Gain and beamwidth are source values. Request patterns at your frequencies with the measurement plane and configuration identified.
  • Confirm the final ordering code, sample appearance and installation drawing; the source sample-page label differs from the electrical-page reference.
  • The summary lists 50–100 W while the electrical table lists 100 W maximum. The final power rating remains to be confirmed.
  • The supplied pattern page shows only the Phi = 90° cut at selected frequencies. Request the required H/E-plane records for coverage assessment.
Request matching datasheet ↗

*Maximum input power is not an unconditional CW or peak rating. Confirm the frequency, duty cycle, installation and approved specification. Separate operating bands do not imply continuous coverage between configurations. Gain and beamwidth may vary with frequency.

Need another configuration? ↗

APPLICATIONS & PROJECT FIT

Put the antenna
in its working context.

Use the application to define the selection requirements. The final antenna depends on the frequencies, coverage geometry, RF chain and installation conditions of your project. The engineering guide Directional Antenna Selection for an Authorized C-UAS RF Chain develops the selection and interface questions in more detail.

AI illustration of a pole-mounted panel antenna with brackets and coaxial feed at an industrial site
AI APPLICATION ILLUSTRATION

01 / FIXED WIRELESS LINKS

Direct the coverage
toward a known location.

Review a panel configuration for a fixed installation with a defined target direction.

Bring to the review

Endpoint geometry, operating band, polarization, coverage angle and mounting height.

Discuss this application ↗
AI illustration of a supported horn antenna connected to an RF instrument on a laboratory bench
AI APPLICATION ILLUSTRATION

02 / RF TESTING & LABORATORY

Evaluate a defined
directional RF path.

Consider a horn reference for controlled RF testing within its specified operating window.

Bring to the review

Test frequencies, H/E-plane requirements, power conditions, fixtures and measurement geometry.

Discuss this application ↗
AI illustration of a panel antenna mounting bracket and coaxial cable routed into an equipment enclosure
AI APPLICATION ILLUSTRATION

03 / EQUIPMENT INTEGRATION

Fit the antenna
to the equipment.

Match the physical antenna and RF interface to the available enclosure or mounting structure.

Bring to the review

Installation envelope, bracket layout, cable route, connector access and nearby structures.

Discuss this application ↗
AI illustration of a tripod-mounted directional panel, receiver and laptop facing a field telemetry station
AI APPLICATION ILLUSTRATION

04 / TELEMETRY LINKS

Review coverage
along the required path.

Assess a directional reference for a telemetry installation with known or controlled pointing requirements.

Bring to the review

Operating band, pointing or movement conditions, required coverage and feedline arrangement.

Discuss this application ↗

AI-generated application illustrations based on antenna reference imagery. Final antenna configuration, installation and suitability require project review; these are not customer deployment or test records.

CUSTOMIZATION & RF INTEGRATION

Match the installation.
Review the complete RF path.

Use an existing reference as a starting point, or submit the changes your equipment needs. Confirm feasibility, the mechanical drawing and acceptance criteria before defining a custom configuration.

ANTENNA & AMPLIFIER MATCHING

RF source→Amplifier→Feedline→Antenna

Review more than
frequency overlap.

Match amplifier output and operating mode to the antenna's agreed input-power limit. Check VSWR, impedance, connector mating, cable loss and the required duty cycle.

01

Frequency & coverage

Required band, gain targets, coverage angle and polarization. A change in one requirement may affect the achievable configuration.

02

Connector & mounting

RF interface, cable exit, bracket or fixture, antenna dimensions and installation environment.

03

Prototype & acceptance

Sample scope, measurement frequencies, documentation, agreed limits, quantity and delivery schedule.

Explore custom antenna development ↗
Share the project requirements→Review feasibility and configuration→Confirm specification and drawing

Customization options, sample scope and timing are confirmed for the selected project.

SPECIFICATIONS & ENGINEERING EVIDENCE

Review the evidence
for the selected configuration.

Request the matching specification and available measurement records. Agree the required frequency points, operating conditions and acceptance limits before final selection.

Original page illustration of a directional antenna mounting fixture and RF connector
MOUNTING & RF INTERFACE ILLUSTRATIONConfirm the drawing.
Identify the exact configuration.

Original installation illustration. The selected model, bracket and connector follow the approved drawing.

01 / ELECTRICAL

Parameters with definitions

Frequency, gain, beamwidth, polarization, impedance and maximum input-power conditions.

02 / COVERAGE

Patterns at the required frequencies

Identify the H/V or H/E plane, frequency, mounting orientation and configuration represented by each record.

03 / RF PERFORMANCE

VSWR sweeps for the selected band

Confirm the actual sweep range and agreed limit. Resolve any difference between the electrical table and the supplied trace.

04 / MECHANICAL

Drawing and document revision

Check dimensions, connector access, fixture details and final ordering code against the released specification.

BEFORE YOU SELECT

Directional antenna
selection FAQ.

Clarify the remaining coverage, integration and purchasing questions before requesting a recommendation.

When is a directional antenna suitable?

A directional antenna concentrates its coverage toward a selected direction. Review the target area, antenna orientation and radiation pattern. If coverage is needed around the installation, compare omnidirectional antenna options. For a configuration-specific engineering example, see 1430–1444 MHz Panel Antenna: Coverage and Outdoor Installation.

Does higher gain always mean a better antenna?

Choose gain together with beamwidth, pointing accuracy and the area to cover. A maximum gain value does not describe every frequency or direction. Review the selected configuration and its frequency-specific pattern.

Do the listed panels support MIMO or dual polarization?

The supplied references specify vertical, single-polarized panel antennas. That does not establish MIMO capability, dual polarization or a particular port count. Confirm the required port arrangement and configuration before selection.

Can I use these antennas with my RF power amplifier?

Review the antenna’s input-power limit and the amplifier’s output, operating mode and duty cycle, together with VSWR, impedance, connectors and cable loss. A maximum value alone does not establish a CW or peak rating.

Can I request a Yagi antenna or a different operating band?

Yes, you can submit the required band, coverage and installation constraints for feasibility review. This page documents panel and horn references; availability and a matching specification for another structure must be confirmed. For the measurement and evidence questions behind this review, see Horn Antenna Mounts for Repeatable RF Amplifier Measurements.

What is needed for a custom antenna quotation?

Share the operating frequencies, coverage or gain targets, polarization, input power and duty cycle, RF connector, mounting space and installation environment. Add quantity, timing and required test records when available.

Which documents should I confirm before ordering?

Confirm the final ordering code, electrical specification, mechanical drawing and applicable revision. Request available VSWR sweeps and patterns for the selected frequencies. Resolve any model-label, rating or measurement differences before acceptance.

REQUEST A DIRECTIONAL ANTENNA REVIEW

Tell us the band.
Show us the installation.

Share the operating frequencies and the area or direction to cover. Add a reference from the comparison, or describe a custom requirement.

  • Frequency & bandwidth
  • Coverage angle & polarization
  • Input power & operating mode
  • Connector & cable route
  • Mounting space & environment
  • Quantity & project timing
What the review should resolve

A suitable reference or feasibility route, the matching specification and drawing, and any remaining operating conditions to confirm.