A horn antenna mount needs a documented mechanical datum and a repeatable relationship to the measurement coordinates. A rigid-looking fixture is not sufficient evidence of repeatable antenna placement.
Define the mechanical reference
Use the antenna and fixture drawings to identify the locating surface, angle-setting feature, rotation axes and transformation into measurement coordinates. Keep cable or waveguide clearance and specified loads and fastening requirements with that drawing. Request an actual mounting drawing for directional antenna candidates; an enclosure edge is not automatically the horn’s electrical reference point.

Separate support from the RF connection
Support the antenna mass and attached transmission hardware without transferring unapproved bending or twisting loads into the RF joint. Coaxial and waveguide interface guidance identifies the connection boundaries to inspect. Preserve access for the specified inspection and calibration steps.

Establish a baseline before removal
First repeat the selected measurement without removing the antenna. Then perform the approved remove-and-refit sequence with the same coordinates and instrument settings, retaining every repetition and deviation. Agree the required assembly and repeatability files against the factory testing and documentation scope. Compare the two sets to investigate variation; do not subtract their spreads and label the difference pure mounting error.

A remove-and-refit repeatability log
Repeatability belongs to the complete fixture and connection method. Record the setup before comparing repeated readings.
| Step | Record | Interpretation |
|---|---|---|
| Establish datum | Mechanical reference, orientation and alignment method | Define how the horn returns to the same position |
| Document assembly | Mount revision, cable routing and specified fastening method | Avoid undocumented assembly changes |
| Compare sequences | Without-removal repeats and each remove/refit result under aligned conditions | Retain the measurement baseline alongside refit variation |
| Assess variation | Spread of the selected metric and measurement uncertainty in both sets | Investigate geometry, RF connection and instrument contributions; do not assume additive error |
Use the applicable fastening and loading limits. If a cable moves, record a changed RF path rather than assigning all variation to the mount. Use VSWR and return-loss interpretation when the repeated measurement concerns connector reflection.
Protect the aperture and mating surfaces during transport, and remove protective items unless their use during measurement is specified. Changes to covers or enclosures need the antenna radome materials review. Deliver the mount drawing, handling method and repeatability record for the actual configuration; antenna selection remains a separate pattern and interface review.
Provide the horn interface drawing, mounting datums, and repeatability requirements for your fixture.