Converting VSWR to return loss requires a consistent reflection definition, sign convention, frequency, and reference plane. They do not independently prove low cable loss, adequate power handling, or compatibility with every connected device. Begin a cable-report review by identifying the assembly, frequency span, termination, and calibration plane.
Read the sign and definition
For reflection-coefficient magnitude r, VSWR = (1+r)/(1−r) and positive return loss RL = −20 log10(r) dB. S11 log magnitude has the opposite sign from RL. The RF amplifier specification guide distinguishes port-match quantities from gain and power specifications.

The Keysight measurement reference explains reflection reporting. The calculation below converts one passive-port example between representations; it is not an acceptance limit.
For the conventional passive port case with VSWR greater than 1, RL = 20 log10((VSWR + 1)/(VSWR − 1)), with RL expressed as positive return loss in dB. As VSWR approaches 1, the ideal return loss approaches infinity; exact unity is a limiting case rather than a finite calculator result. Retain the reflection-coefficient definition when comparing RL and S11 signs.
For a passive example with reflection-coefficient magnitude 0.1, the following quantities describe the same reflection at the same reference plane.
| Quantity | Calculation | Result |
|---|---|---|
| Return loss | −20 log10(0.1) | 20 dB |
| S11 log magnitude | 20 log10(0.1) | −20 dB |
| VSWR | (1 + 0.1) / (1 − 0.1) | 1.222… : 1 |
Check how the cable was measured
Before conversion, align frequency points, termination, included adapters and calibration plane using the S-parameter measurement method. If the assembly uses transitions, consult coaxial and waveguide interface guidance to identify the included boundaries. Then compare representations at that same plane.

Read insertion loss separately: a lossy cable attenuates both forward and reflected waves, so an improved input reflection number need not mean a lower-loss cable. RF amplifier VSWR protection is another separate question; this reflection conversion does not establish load-mismatch survival.
Compare against the agreed limit
After aligning context and converting representation, compare each point with the agreed frequency-dependent limit. Keep the worst point, raw trace and assembly identity in the RF interface control document. Inspection or repeat testing follows the approved procedure; no universal cable limit is supplied here. Use the RF integration support route to define the hardware interfaces, supplied scope and records needed for the proposed installation.

If two reports still differ, RF amplifier test-report comparison separates missing context from a contradictory matched result. A correct VSWR-to-RL conversion cannot repair a different termination or calibration plane.
Share the cable assembly, termination, frequency range, and report-boundary questions relevant to your RF connection.