Covering 400 MHz to 6 GHz on a single RF test path usually calls for more than one antenna, since the two CorelixRF directional antennas discussed here each span only part of that range. The practical question for an RF engineer or lab manager is how to pair them so the coverage is continuous, and how to judge the point where responsibility shifts from one antenna to the next. This guide works through that decision using two CorelixRF products as a concrete example.

Before comparing antennas, it helps to define what the test path actually needs: a continuous sweep across the full 400 MHz–6 GHz range, or a set of discrete frequency points used in a fixed test sequence. These are different problems. A continuous sweep needs a handover point somewhere in the frequency domain where performance on both sides is acceptable. A discrete test sequence only needs each individual frequency point covered, and the number of antenna changes depends on the order those points are tested in, not on where a nominal frequency boundary happens to fall.

Either way, the starting point is the same: know the frequency range or point list, the required field strength or power at each frequency, and any constraints on test geometry, polarization, or available amplifier power. These requirements, not the antenna datasheets alone, are what ultimately decide whether a two-antenna or segmented configuration is appropriate.

The CRF-DA-400M2700M-6-12dBi and CRF-DA-2000M6000M-13.16-19.07dBi are two directional antennas from CorelixRF whose nominal frequency ranges overlap between 2000 MHz and 2700 MHz, making combined coverage from 400 MHz to 6000 MHz possible in principle.

The gain figures are the nominal gain range stated across each antenna’s full frequency band, while the VSWR figure is a specified upper limit rather than a range — the two parameters describe different things and shouldn’t be read as the same kind of min/max value. In this configuration, the CRF-DA-400M2700M covers the lower portion of the test range, while the CRF-DA-2000M6000M extends coverage up to 6 GHz; the 2000–2700 MHz overlap gives some flexibility in where the transition between them is placed, but the actual assignment should be based on measured performance and the requirements of the test setup rather than on the overlap alone.

Technician checking a mounting bracket beside a silver horn antenna

A nominal frequency range tells you an antenna can operate across that span; it does not tell you what gain or VSWR it will show at any single frequency within it. Where the test requires a specific frequency inside the overlap band — a point near 2400 MHz, for instance, used here only as an example — the gain and VSWR of each antenna at that exact frequency should be obtained from CorelixRF rather than estimated from the range endpoints. Requesting the measured curve for the relevant segment of the band is the reliable way to compare the two options at that frequency.

VSWR describes how well the antenna is matched to the feedline. A VSWR of 2.0:1 corresponds to a return loss of about 9.54 dB, meaning roughly 11.1% of incident power is reflected and about 88.9% is accepted by the antenna; this is distinct from the fraction of accepted power that is ultimately radiated, which depends on the antenna’s radiation efficiency. The VSWR figure in the datasheet is a maximum commitment across the stated frequency range, so actual performance at a given frequency may be better, and a measured VSWR curve is worth requesting when the application is sensitive to matching.

Amplifier compatibility follows from the gain and power figures at the frequencies actually used. Because gain is not constant across a wide band, the power needed from the amplifier to reach a given field strength will differ across an antenna’s range, and the exact relationship should be worked out from the measured gain at the frequencies in question rather than assumed from the published range. For EMC immunity testing, amplifier output should be set according to the field calibration procedure in use for the test, adjusting as needed across the swept range rather than treating any resulting field strength variation as acceptable by default.

Connector type and feedline also factor into the usable power and loss at the antenna input. The CRF-DA-400M2700M uses an SMA-K connector, while the CRF-DA-2000M6000M uses an N-J connector; where a system needs to interface both, an adapter will add some insertion loss and should be accounted for in the power budget. Feedline loss increases with cable length and generally tends to increase with frequency as well, so a cable adequate at the lower end of a band may contribute more loss near the top of it. Both antennas list a 100 W power handling rating; whether this applies under CW, pulsed, or other operating modes, and over what frequency and connector conditions, should be confirmed against the complete datasheet rather than assumed.

Disconnected coaxial connector, adapter and mounting bracket on a workbench

Two-antenna coverage, such as pairing the CRF-DA-400M2700M with the CRF-DA-2000M6000M, can be a reasonable starting point for evaluation when the priority is minimizing the number of antennas, switch channels, and calibration datasets in the system. Whether it’s suitable depends on the actual gain, power, and VSWR performance at the frequencies the application uses, measured against the system’s requirements — not on an assumption that wider coverage per antenna is automatically sufficient.

A segmented approach using three or four narrower-band antennas may offer performance better optimized to a given sub-band, since each antenna covers a smaller span. This comes at the cost of additional antennas, more RF switch channels, and more calibration datasets to maintain, and whether that tradeoff is worthwhile depends on the specific gain and VSWR data for the products under consideration, not on a general assumption that narrower bands perform better. Which configuration makes sense depends on the application: a lab running frequent full-band sweeps with amplifier capacity to spare may find two antennas workable, while a lab with specific frequency points or sub-bands that the wideband antennas cannot be confirmed to meet may find segmented coverage the more defensible choice.

Where a test sequence revisits certain frequencies repeatedly, the order of testing can also factor into which antenna handles a frequency in the overlap band — for instance, in a sequence like 800 MHz → 2400 MHz → 800 MHz → 5800 MHz, assigning the 2400 MHz point to one antenna rather than the other can reduce the number of antenna changes, once both antennas are confirmed to meet the requirements at that frequency. This kind of sequencing is a secondary consideration that follows performance verification, not a substitute for it.

Horn antenna and disconnected coaxial cable beside instruments with dark displays

CorelixRF manufactures its directional antenna products and can help work through a specific 400 MHz–6 GHz configuration, whether that ends up being a two-antenna pairing, a segmented setup, or something in between. To get a useful starting point for that conversation, it helps to share the frequency range or test points involved and their order, the power, field strength, or waveform requirements at those frequencies, and any antennas, feedline, or connectors already in place.