The CRF-PA-500M2000M-100W is a GaN solid-state RF power amplifier specified for 500 MHz–2 GHz with 100 W rated output power. It is a practical starting point for a test bench, communications subsystem, RF-interference or EW work, or an aerospace-control system that needs one documented band and a rack-integrated power stage. The useful selection question is where the 100 W must exist in the signal path, under which waveform and load conditions, and which controls the finished system must expose.
Use the supplied configuration as the source baseline. The figures below retain the source’s Min., typ., and max. labels and guide early system integration checks.
Define the output before choosing the amplifier
A 100 W requirement can mean power at the amplifier output connector, power after a cable or switch, or power delivered at a fixture, antenna, chamber feed, or device under test. Those reference planes are separated by cable loss, connector repeatability, couplers, sensors, and load match. Write the required reference plane into the system specification first, then choose the drive level and margin around that plane.
The source electrical table is based on a 50 Ω system and lists a 5 dBm maximum input power. That input limit is separate from the 100 W rated output. A source or attenuator should therefore be specified with the required waveform, drive range, and protection path rather than inferred from the output number.
Source configuration at a glance
The supplied CRF-PA-500M2000M-100W data gives the following starting configuration. “Min.”, “typ.”, and “max.” retain the meaning used by the source.
| Field | Supplied value | Integration use |
|---|---|---|
| Frequency range | 500–2,000 MHz | Check every source, switch, cable, sensor, load, and fixture against the full band. |
| Rated output power | 100 W | Bind the required 100 W to the chosen RF reference plane and waveform. |
| Gain / flatness | 50 dB minimum gain; −3 to +3 dB gain flatness; gain control up to 20 dB | Set drive and control requirements from the gain definition; do not treat gain flatness as gain. |
| Input boundary | Input impedance / VSWR: 50 Ω / 1.5:1 typ.; input power: 5 dBm max. | Confirm source compatibility and keep the input limit separate from output power. |
| RF interfaces | SMA-F input and N-F output, front panel | Check mating hardware, cable ratings, clearance, and the measurement plane. |
| Control | RS485 / LAN | Map commands, status, alarms, and reset behavior to the bench controller. |
| Supply / consumption | AC 220 V ±10%, 50/60 Hz; 500 W typ. consumption | Reserve the correct AC service and rack thermal budget. |
| Mechanical / environment | 19-inch 3U rack mount; 16 kg typ.; 0 to +50 °C; air cooling | Check rack space, support, airflow, service access, and ambient conditions. |
| Spectral fields | Harmonics −10 dBc typ.; spurious −60 dBc max. | Keep the field definitions and test conditions in the project acceptance record. |
The source notes that values are based on the supplied product configuration and remain subject to final production test and project-specific customization. Final mechanical dimensions are subject to the production unit.

Build the RF path around the reference plane
Draw the complete path from signal source to load: source, attenuation or level control, cable, switch, coupler, sensor, amplifier, and the final load or DUT. At 500 MHz–2 GHz, the path components still need their own band and power ratings. The installation record should state where power is measured, whether cable or fixture loss is removed, the load condition, and which input drive was applied.
For a repeatable operating record, capture frequency or frequency points, waveform type, CW or pulse mode, duty cycle, input level, output reference plane, load VSWR, ambient temperature, supply condition, control interface, and any alarm or protection event. For an installation result, bind any future reading to its frequency, input, output reference plane, load, waveform, supply, temperature and calibration context; the supplied datasheet remains the specification baseline.
Plan the 3U rack, supply and airflow
The specified mechanical format is a 19-inch 3U rack mount with 16 kg typical weight. The source lists AC 220 V ±10% at 50/60 Hz and 500 W typical power consumption, with air cooling. Reserve rack support, intake and exhaust clearance, service access, and the AC circuit before the amplifier is placed in a closed enclosure. The 0 to +50 °C operating range is a source condition; it does not replace an enclosure-level thermal review.
Mechanical drawings are supplied for installation reference, while final dimensions follow the production unit. Keep the drawing, mounting details, cable bend radius, and airflow direction with the system build record.

Map control, monitoring and protection
The source lists real-time temperature and current monitoring, alarm and fault functions, over-temperature, over-drive, over-voltage, and load-mismatch protection. Input power detection and forward/reverse power monitoring are optional in the supplied data, and a GPIB programmable control interface is also listed as optional. Treat those options as configuration items to confirm in the quotation, not as features guaranteed by the base model name.
RS485 and LAN are the listed control interfaces. The system record should identify which interface is used, which status and alarm signals are read, how a fault is cleared, and which external interlock or load condition stops the test.
Check fit for the intended application
This 500 MHz–2 GHz, 100 W configuration fits projects that need a documented wideband solid-state stage for test and measurement instrumentation, communications systems, RF interference or EW system-level testing, or aerospace control work. It can also be considered for a custom RF integration where the signal, load, mechanical, control, and environmental requirements are specified together. The frequency and power label alone does not decide fit: waveform, duty cycle, load, reference plane, cooling, and acceptance data still belong in the project definition.
For a broader product comparison, review the available RF power amplifier platforms. For an adjacent lower-frequency, higher-power EMC example, see the 80 MHz–1 GHz 500 W EMC and wideband testing guide; its power class and band are different from this 100 W configuration.
Discuss the CRF-PA-500M2000M-100W integration
For an RFQ or configuration review, send the target operating band, required output at its reference plane, waveform, CW or pulse operation, duty cycle, input drive, gain-control needs, load VSWR, SMA-F/N-F or other connector requirements, rack and cooling conditions, supply, RS485/LAN or optional control needs, protection expectations, mechanical constraints, and the factory test data or drawing required for acceptance. Include the relevant system drawing so the configuration can be checked against the installation. Contact CorelixRF about this RF requirement