For an authorized 1–2 GHz RF test system, amplifier selection is an RF integration decision. This page uses the CorelixRF CRF-PA-1000M2000M-1000W as a reference and focuses on the checks that determine whether a cabinet amplifier can connect to the source, load, facility supply and cooling path. The source-listed 1,000 W minimum RF output is a component reference, distinct from any measured value at another point in the RF chain. The amplifier is one component in that chain; system-level performance, range, interference results and hit rate require separate project evidence.
What Engineers Need to Decide First
Before comparing output figures, define the operating band, the output definition (source-listed minimum or measured), waveform and duty cycle, load and VSWR condition, drive limit, and cabinet constraints. Broader platform choices can be reviewed on the RF amplifier platforms page; the reference values below then give the integration team a concrete starting point.
CRF-PA-1000M2000M-1000W Reference Values
The following values are taken from the supplied datasheet for the specified model. They are selection inputs, not a complete system specification.

| Model | CRF-PA-1000M2000M-1000W |
|---|---|
| Frequency range | 1,000–2,000 MHz |
| RF output power | 1,000 W minimum |
| Gain | 60 dB minimum |
| Gain flatness | −3 dB to +3 dB |
| RF connectors | RF input: N-Female, front panel; RF output: L29-Female, rear panel |
| Control interface | RS485 / LAN |
| Power input | AC 380 V ±10%, 50/60 Hz; three-phase five-wire aviation connector |
| Typical consumption | 7,000 W typical |
| Form factor and cooling | Cabinet; air cooling |
| Operating temperature | 0 to +50 °C |
| Input conditions | typical input impedance 50 Ω; maximum input VSWR 1.5:1; maximum input power 5 dBm |
| Mechanical reference | Cabinet dimensions to be confirmed; 250 kg typical weight |
The datasheet states that the electrical table is based on a 50 Ω system, the rated AC input supply and a standard production test configuration. Values are based on the supplied product configuration and remain subject to final production testing and project-specific customization. Keep minimum, maximum, typical and rated values separate when building the cabinet requirement.
Cabinet Integration Checks
RF path and load
The front-panel input is N-Female and the rear-panel output is L29-Female. Confirm mating connectors, cable assemblies, adapters and the load before release; if an external antenna is part of the approved arrangement, check the RF antenna separately from the load qualification. The datasheet gives a typical 50 Ω input impedance and maximum input VSWR of 1.5:1; it does not provide a complete system mismatch result for every external load.
Facility supply
Plan around AC 380 V ±10% at 50/60 Hz, a three-phase five-wire aviation power connector and 7,000 W typical consumption. Facility engineering must confirm the actual supply, protective devices, wiring and commissioning procedure. The listed consumption does not establish input current, efficiency or site capacity by calculation.

Cooling and mechanics
The reference unit uses air cooling and is specified for 0 to +50 °C operation. The datasheet leaves cabinet dimensions to be confirmed and lists 250 kg typical weight. Obtain the final mechanical drawing, airflow clearances, floor or rack limits and service access requirements before fixing the cabinet layout.
Control, monitoring and protection
RS485 and LAN are listed as control interfaces. Temperature and current diagnostics with alarm protection are listed; forward/reverse monitoring, input-power detection, LAN remote monitoring and GPIB programmable control are optional items in the source document. Confirm which functions belong to the ordered configuration. The source also lists over-temperature, over-drive, over-voltage and VSWR protection or alarm functions; these entries do not replace an external load and interlock review. A related configuration review is 1-2 GHz 500W RF Power Amplifier Facility Requirements Brief. Keep its ratings, interfaces and installation conditions distinct when comparing it with this setup.
Prepare an Authorized RF Integration Request
Contact the CorelixRF engineering team with the band and RF-output reference plane, waveform and duty cycle, source and load path, facility supply and cooling limits, and cabinet constraints. Include the required RS485/LAN protocol, monitoring and alarm behavior, protection expectations, and final mechanical drawing or production-test documents so the ordered configuration can be checked against the test requirement. For the component portion of the requirement, review the RF front-end platform scope and keep its hardware responsibilities separate from complete-system outcomes.