The CorelixRF CRF-PA-18G40G-70W-M connects a coaxial source path to a WRD180 waveguide output over 18–40 GHz. Its 70 W specification is minimum saturated output power, Psat. That distinction matters before selecting the load, calibrating the output path or promising a linear signal level to the next device.
The electrical values use a 50 Ω system and the standard production test configuration. Keep that basis with the selected waveform, operating duration and installed cooling conditions when agreeing the output test.
Treat the input and output as different mechanical interfaces
| Connection | Specified entry | Work to resolve |
|---|---|---|
| RF input | 2.92 mm-F; 3 dBm maximum input | Confirm source cable and drive at the input plane. |
| RF output | WRD180 | Obtain the actual flange drawing, mating hardware and approved transition. |
| Control | RS485 / LAN | Agree commands, states and alarms before automation. |
| Supply | AC 220 V ±10%, 50/60 Hz; 1,600 W typical consumption | Use the final electrical installation requirements for circuit sizing. |
A WRD180 label is a starting point for the output assembly, not a complete fabrication drawing. Confirm flange geometry, orientation, fastening method and the transition to the coupler or load. Support the downstream assembly so its weight and cable forces do not become an uncontrolled load on the amplifier port. Use the specified fastening procedure; a torque borrowed from a different waveguide assembly is not a justified installation value.

Keep Psat separate from the useful linear level
The datasheet lists 70 W minimum Psat, 49 dB minimum small-signal gain and ±8 dB maximum small-signal gain flatness. These are different properties. Small-signal gain describes a low-drive condition; Psat describes saturated output. A modulation requirement needs its own average power, bandwidth and distortion limits. The 70 W figure alone does not establish P1dB, EVM or intermodulation performance.
Measured power can change across a frequency sweep because the amplifier and the rest of the RF path both have frequency-dependent responses. A calibrated path and a defined output reference plane help separate those effects.
Choose whether the required result is at the amplifier flange, after a transition, or at the DUT. Characterize loss at the actual frequency points and record the adapter arrangement. A gain-flatness entry cannot be substituted for a constant full-power output curve. Keep the output definition and input drive with every test result so a later change of transition does not silently change the comparison.
Support the 40 kg assembly and its air path
The mechanical entries are 432 × 635 × 333.4 mm and 40 kg. Check the rack support, handling route and service access against the released drawing. Do not infer rail geometry or a front-panel connector layout from a generic rack photograph. The waveguide assembly also needs space for removal without shifting the amplifier or disturbing nearby connections.

Air cooling and 0 to +50 °C operation are specified. Plan the inlet and exhaust path with the surrounding rack equipment, then check the installed inlet condition during the intended run. The 1,600 W consumption entry is typical, so it is not a maximum branch-circuit rating. Ask for the delivered unit’s electrical requirements, protective-earth arrangement and startup demand before finalizing facility power. Use the 18–40 GHz amplifier platforms page to compare the product family, then request the exact configuration and evidence required by this review.
Resolve control behavior before the first driven sweep
RS485/LAN is listed, with temperature and current diagnostics; forward/reverse power monitoring is optional. The protection list includes alarms, over-temperature, over-drive and VSWR protection, but provides no numerical trip values or reset sequence. Define which signals the host can read, how it removes RF drive and what must be checked before restarting. Do not add over-voltage protection to this configuration without supporting documentation.
Before enabling the source, confirm a suitable terminated output path and establish the source limit at the amplifier input. Start below the intended driven condition and advance under the agreed procedure while watching output and operating state. The 3 dBm input maximum is a limit, not an instruction to start a sweep at that level.