The CorelixRF CRF-PA-6000M18000M-80W is a 6–18 GHz GaN amplifier with N female RF input/output and a 19-inch 3U rack-mount package. Its electrical table lists 80 W minimum output and 50 dB minimum small-signal gain. Assess it as part of the source-to-load chain, including available drive, path losses, cooling and the output definition needed by the test.

Define the signal before using the output rating

The electrical reference uses a 50 Ω system, rated AC input and standard production test configuration. Its output row does not identify P1dB, saturated output or a modulated linear average-power limit. State the actual frequency points, waveform, occupied bandwidth and duration, and obtain the output conditions applicable to that requirement. Coverage across 6–18 GHz does not define the instantaneous modulation bandwidth.

Item Specified reference Bench use
Output / gain 80 W minimum; 50 dB minimum small-signal gain Confirm the working point with transfer data
Drive 0 dBm maximum input Set lower initial drive and review presets
RF path N female input and output Rate the complete cable, coupler and load assemblies
Installation AC 220 V ±10%, 50/60 Hz; 3U; air cooling Reserve supply, airflow and service access

Give the source a controlled adjustment range

Small-signal gain is 50 dB minimum, small-signal gain flatness is −5 to +5 dB, and gain-control range is 20 dB maximum. These entries help identify source-adjustment needs, but do not determine the input required at high output. Obtain the output-versus-input response at the relevant frequencies and waveform. Keep the 0 dBm input maximum separate from the agreed starting level.

A source preset, calibration routine or upstream amplifier can change the drive reaching the input. Review those states as well as steady operation. A protected amplifier still needs a controlled source; the protection list does not specify an allowable overdrive exposure or complete recovery behavior.

Keep the coaxial path within its own ratings

N-Female input and output simplify many coaxial lab chains, but cable loss and load power rating still need review. Check the frequency, power and mismatch ratings of cables, adapters, couplers, switches and termination under the intended signal. The connector family alone cannot establish the complete assembly’s rating or its behavior across the whole band.

Measured power can change across a frequency sweep because the amplifier and the rest of the RF path both have frequency-dependent responses. A calibrated path and a defined output reference plane help separate those effects. Retain the load identity, path-loss treatment, sensor range and operating duration when comparing results from different bench arrangements.

Plan the full 3U installation

The specified supply is AC 220 V ±10%, 50/60 Hz, with air cooling and a 0 to +50 °C operating range. Obtain the production drawing, depth, support and airflow requirements before assigning the rack position. A 3U height does not include cable bends, connector handling, exhaust clearance or service access. Review nearby heat sources and the intended run duration.

RS485/LAN control and temperature/current monitoring are listed. Forward/reverse power monitoring and LAN remote monitoring are optional. Confirm the delivered protocol, channels and units before writing host software. The sheet lists over-temperature, over-drive, over-voltage and VSWR protection/alarm functions without complete numeric thresholds or reset timing; agree the source response and fault recovery required by the bench. For a related test review in this frequency range, see Choosing a 6–18 GHz 50W Amplifier for an EMC Test Rack. Apply its checks with the stated configuration and measurement conditions.

The test-data evaluation guide helps turn bench conditions into evidence requests. For this model, ask for frequency-point output and gain data with source levels, waveform, load, reference planes and thermal conditions. Keep the model’s output definition separate from power measured after the installed path.

Compare 6–18 GHz microwave amplifier platforms if the required band, output or installation differs. Send the source-to-load diagram, signal definition, required power plane, available drive, rack envelope and host functions for an 80 W bench review. Include the actual channels and duration so the proposed configuration can be assessed against the intended work.