Select an 18–40 GHz RF power amplifier from the frequencies and power needed at the load. Full-band coverage is useful when one bench must serve several microwave test windows. A project using a smaller frequency window should state that window first, then compare the available configurations against its gain, output and interface requirements.

CorelixRF’s 18–40 GHz datasheets include 5 W, 20 W, 40 W and 70 W output classes. They are separate configurations with different supplies, controls and mechanical information. The product name alone is insufficient to carry those details from one power class to another.

Compare configurations before choosing rack hardware

Datasheet output class RF input / output Supply Control in electrical table Mechanical information
5 W 2.92mm-F / 2.92mm-F DC 18 V CAN 250 × 150 × 100 mm, TBD
20 W 2.92mm-F / WRD180 AC 220 V ±10%, 50/60 Hz RS485, LAN 19-inch, 3U
40 W 2.92mm-F / WRD180 AC 220 V ±10%, 50/60 Hz RS485, LAN 19-inch, 4U
70 W 2.92mm-F / WRD180 AC 220 V ±10%, 50/60 Hz RS485, LAN 432 × 635 × 333.4 mm

The 5 W sheet leaves the mechanical configuration pending. The 20 W, 40 W and 70 W sheets specify air cooling; they do not establish the cooling arrangement for the 5 W configuration. Obtain a released outline and fitted interface list for the unit being ordered before fixing its shelf, power connection or control software.

Separate rated power from the test waveform

Define CW, pulsed, swept or modulated operation, together with run time and ambient conditions. The 5 W, 20 W, 40 W and 70 W figures appear as saturated output power in the electrical tables. They do not establish linear output at a chosen distortion limit, or pulse performance for an unspecified timing profile. Request the output definition that the test needs.

Keep input drive limits with the selected sheet. The 5 W, 20 W and 40 W tables list 0 dBm maximum input, while the 70 W table lists 3 dBm. Those are upper limits, not recommended starting levels. Set attenuation and gain before enabling the source, then increase drive under the test procedure.

Choose the RF path that preserves usable bandwidth

The 5 W configuration uses coaxial input and output. The three higher-power sheets list 2.92mm-F input and WRD180 output. Confirm the mating flange and any transition over the entire operating band. A connector that physically fits does not establish the adapter’s bandwidth, insertion loss or power handling.

A bench driver, a broadband power stage and a measurement amplifier can face different load-side requirements. Calculate cable, switch, coupler and transition loss to the agreed reference plane. Compare output and gain at the frequencies actually used, including band edges, rather than selecting from a single peak value.

Check the space around the enclosure

Rack height covers only part of the installation. Add chassis depth, connector access, cable bend radius, waveguide support and maintenance clearance. The 70 W sheet gives a 635 mm enclosure depth; the rack must also accommodate the connections beyond the enclosure. Do not assume that a rack height mentioned for one configuration applies to the others.

For air-cooled units, describe rack inlet temperature, exhaust clearance, nearby heat sources and intended run time. Recirculated hot air can change the thermal condition even when the room temperature is unchanged. Use the same configuration’s electrical and mechanical records for supply and cooling decisions.

Translate the application into test inputs

The same amplifier class can serve different review tasks. These examples define questions for a test plan; they do not assign a power class or demonstrate a system outcome.

Review situation Inputs to define
Wideband DUT bench DUT input plane and permitted level, frequency-dependent fixture loss, and required output at that plane.
mmWave communications validation Waveform, occupied bandwidth, average and peak requirements, and the relevant distortion criterion.
Authorized controlled RF interference test Documented authorized scope, test boundary, load arrangement and agreed evaluation criterion; amplifier power alone does not demonstrate effectiveness.
Aerospace RF subsystem laboratory validation Subsystem interfaces, waveform and laboratory environmental conditions; a bench result is not flight qualification.
SDR, amplifier and antenna chain Source drive and peaks, path losses, load-side output definition and the controls actually fitted to the selected configuration.

Match control functions and test data to the order

Specify the commands, monitoring fields, fault response and reset behavior needed by the test software. GPIB and forward/reverse power monitoring appear as options in the documentation. Include them explicitly when required; the interface name does not define command syntax, measurement accuracy or fault timing.

Request output and gain versus frequency under the intended waveform and thermal conditions, plus the relevant harmonic or spurious results. Keep fixture losses and the calibration plane with those results. The 18–40 GHz RFQ checklist covers the information to send, while the amplifier measurement guide helps define comparable records.

Compare 18–40 GHz amplifier platforms against the required band, load-side output, interfaces and facility limits. Send those requirements and the selected datasheet revision when you request an 18–40 GHz configuration review.