The CorelixRF CRF-OA-2400M2500M-4.7-8dBi is a vertically polarized omnidirectional antenna specified for 2400–2500 MHz. Field selection depends on the coverage geometry, antenna height, feedline, mount and power applied at the antenna connector. A matching frequency label is only the start of that check.
Read the electrical and mechanical entries together
| Item | Datasheet entry |
|---|---|
| Frequency | 2400–2500 MHz |
| Gain | 4.7 dBi minimum, 8 dBi maximum |
| Polarization / impedance | Vertical / 50 Ω |
| VSWR | <2.0 |
| Power | Header: 50–150 W; electrical table: maximum 150 W |
| Connector / cable | Bottom N-J / no cable supplied |
| Dimensions / mass | Φ20–Φ32 × 600 mm / approximately 2 kg |
| Materials | Copper element / fiberglass radome |
Use the exact operating channels when checking frequency coverage. A wider-band source or amplifier must not drive the antenna outside its specified range. Keep the selected antenna configuration and its released data with the installation record; the 4.7–8 dBi range does not mean 8 dBi is available at every frequency and elevation angle.
Use the pattern to choose height and orientation
Omnidirectional coverage describes the horizontal coverage objective. It does not establish uniform radiation in every direction or a guaranteed coverage radius. Check the vertical pattern against the intended receiver heights and distances. Increasing gain can concentrate energy into a narrower elevation region, so mast height and tilt can change which locations receive useful coverage.
The documentation includes horizontal and vertical pattern plots at 2400 and 2500 MHz. Obtain the corresponding configuration, mounting conditions and test record if those plots will support a site decision. Nearby metalwork, brackets, vehicles, buildings and other antennas can change impedance and the installed pattern.
Choose the mounting style before arranging the feedline
The sheet lists optional mounting styles and shows flange, spring, brace and clamp arrangements. Confirm which assembly is being supplied, its dimensions and its mating hardware before drilling or cutting a bracket. The listed 600 mm dimension should not be replaced by dimensions printed on another mounting variant’s picture.

The connector is listed as N-J at the bottom, with no cable supplied. Verify the mating connector, cable type, insertion loss and bend radius before assembly. Provide strain relief so cable weight and movement do not load the antenna connector. Leave access for assembly and later inspection.

For outdoor installation, confirm the sealing method, radome condition, bracket rigidity, grounding and bonding requirements for the complete site. The datasheet temperature range does not establish an ingress-protection rating, wind-load rating or lightning-protection design. Obtain the applicable requirements before installation.
Match antenna input power to the complete RF path
The sheet’s header shows 50–150 W while its electrical table lists a maximum power of 150 W. It does not define a complete CW, peak or duty-cycle condition for every configuration. Confirm the applicable limit for the ordered assembly and waveform before operation, rather than treating the upper number as blanket approval for a 150 W amplifier.
Account for feedline loss, connector rating, reflected power and the amplifier’s available protection. Confirm any VSWR trip threshold and recovery sequence from the amplifier documentation. Compare omnidirectional antenna options using these antenna-side conditions, not power alone. If this check reveals an unresolved symptom, Antenna Damage and Reflected Power: Localize the Feedline Fault provides a focused path for organizing the investigation.
Check the installed path at reduced power
Before a full-power run, verify channel, polarization, mounting height, cable loss, connector assembly and nearby structures. Start at a reduced level under the approved operating procedure, record forward and reflected power at a defined reference plane, and increase power only after the path has been checked. A bench VSWR result does not establish the final site’s coverage.

Record orientation, mast position, bracket, cable route, sealing method and nearby objects so maintenance teams can reproduce the installation. If the project needs a wider band, compare the 400 MHz–6 GHz omnidirectional antenna guide; its frequency coverage does not transfer its gain or power limits to this model. The antenna product range is the starting point for a different mounting or coverage requirement.
Send the operating channels, coverage geometry, mounting arrangement, cable details and maximum antenna-side power when you request a 2.4 GHz antenna configuration review. Include the required VSWR and pattern records for the actual installation.