RF path-loss calculation inputs must identify the transmitted level, intervening gains and losses, and the receiver criterion before a distance claim can be reviewed. Before comparing test results, define the RF path, the receiving metric, and the conditions under which the result is accepted. This page organizes the evidence behind a path-loss calculation; it does not rank counter-UAS systems by unverified distance.
Name the path and its boundaries
Name the conducted transmitter and receiver planes, feed losses, antenna gains, frequency, polarization and geometry. For an authorized UAV link, the UAV link budget review locates the amplifier within that particular chain. When directional coverage is required, use directional antenna selection to examine the pattern rather than treating peak gain as coverage.

Use P_rx = P_tx − L_txfeed + G_tx − L_path + G_rx − L_rxfeed − L_other. A hypothetical set of inputs is 40 dBm − 2 dB + 6 dBi − 80 dB + 3 dBi − 1 dB − 0 dB, giving −34 dBm at the named receive connector. Here the antenna gains use an isotropic reference and the path term follows that convention. These assumed values describe a budget, not a CorelixRF measurement, allowed radiated level or operating distance.
Separate calculated and observed loss
Compare the modeled and observed connector levels only after aligning frequency, feed corrections, antenna orientation and instrument settings. Record each mismatch beside the affected budget term. Leave an uncharacterized obstruction or multipath effect unknown rather than absorbing it into an unexplained margin.

A level difference that remains after that alignment still needs attribution. RF path-loss troubleshooting separates hardware-path changes from environmental changes; a single received-power difference does not identify the failed component.
State what the result establishes
The review should produce a reproducible budget and a list of unresolved inputs. Report a test outcome only against its stated receiving criterion and conditions. Component gain or output power is not proof of identification, mitigation, or reliable operation at a claimed distance.
Inputs for a defensible path-loss statement
Keep the power plane and correction method beside each term. The noise-figure reference-plane review illustrates the same plane-alignment problem in noise measurements, where moving a plane changes which input loss is included.

| Input | Required context | What it can support |
|---|---|---|
| Conducted output | Waveform, average/peak definition and connector plane | Power available at the named port |
| Feed and antenna | Measured loss, pattern, polarization and mounting | A stated radiated-path model |
| Propagation | Geometry and the chosen model assumptions | A conditional prediction |
| Receiver outcome | Sensitivity or quality criterion and observation conditions | A result under those conditions |
In the hypothetical budget, −34 dBm is a predicted receive level. Without a receiving quality or sensitivity criterion it cannot establish margin, and without the relevant propagation conditions it cannot establish distance. A measured feed loss may still close that one input even while the overall claim remains unresolved. The amplifier and antenna integration page provides the corresponding product and interface path for this chain-level review.
Use the RF gain budget for conducted stage levels and the site measurement baseline for environmental observations. Keep those records distinct from a system-level acceptance decision.
Share the frequency band, path components, calibration boundary, and available loss records for your test chain.