The noise-figure reference plane and the gain-measurement boundary determine which losses and components a reported result includes. A change in input fixture or measurement boundary can change the quantity being compared. This review defines the measurement boundary; it does not replace a complete receiver noise budget.
Draw the measured path
Draw input fixture, module, output fixture and calibration planes. Use the RF amplifier test-bench review to locate the source and sensor, then label the losses included in this result. Keep frequency and operating conditions aligned across runs.

For power gain, retain source display, corrected DUT input and corrected DUT output as separate fields with their corrections. Gain is output dBm minus input dBm at the named DUT planes. For small-signal VNA work, the S-parameter measurement guide covers calibration and reference planes; that procedure does not substitute for noise-figure calibration.
Explain what the noise result includes
Decide whether the report covers the bare LNA or the input path plus LNA. LNA selection needs candidates on the same boundary. A front-end limiter or filter reviewed under LNA input protection contributes its own loss and noise; its protection role does not remove that contribution.

Keep equivalent noise temperature, noise factor, and noise figure definitions separate. Their mathematical relationship is covered in the noise conversion guide. Converting units does not correct an inconsistent reference plane.
Build a comparable record
Use fields for DUT identity, frequency, bias, temperature, calibration state, input/output boundary, corrections, and the metric reported. Retain the raw reading alongside the corrected result where available.

Choose what the measurement includes
The same hardware can produce different reported gain or noise results when the included path changes. Label the measurement boundary in the result table.
| Reported result | Boundary | Required clarification |
|---|---|---|
| DUT gain | DUT input to DUT output | Input/output path corrections and operating level |
| Assembly gain | Named external connectors | Included filters, cables and gain stages |
| DUT noise figure | Defined DUT plane and source conditions | Calibration and input loss treatment |
| Receiver noise performance | Complete declared receiver boundary | Gain states and bandwidth/sideband conventions |
For a matched passive input loss at the noise reference temperature T0, the linear loss L has noise factor L and gain 1/L. With an LNA of noise factor F_A, the loss-plus-LNA assembly has F_total = L × F_A, so its noise figure includes the input loss in dB. That is an assembly result if calibration stops before the loss. A DUT-plane result needs the applicable calibrated loss treatment, not a change of label. The assumptions follow the linear cascade and input-loss treatment in Analog Devices’ system noise-figure analysis.
When a correction is missing, state which comparison remains unresolved. Do not compensate a measurement with a nominal cable-loss figure from a different frequency or configuration. The final deliverable is a boundary-aligned measurement record; receiver gain and noise allocation uses that record as one input.
If the input path temperature, loss versus frequency or calibration endpoint is unknown, retain the whole measured assembly boundary and leave bare-LNA noise figure unresolved. Keysight’s noise-figure measurement documentation describes calibrated loss treatment. Full receiver cascade allocation remains in the separate guide linked above.
Send the module, measurement plane, calibration arrangement, and gain or noise records that need clarification.
Discuss Gain and Noise Test Inputs