RF amplifier efficiency test data need matching electrical inputs as well as RF output readings at the same operating point. The supplied 6–18 GHz files show this distinction: power, small-signal gain and input VSWR records are available, but the stored current values cannot support a verified efficiency result.
Keep the measured quantities separate
The raw sweeps contain 121 frequency points from 6 to 18 GHz at 100 MHz intervals. The following values summarize those stored points. They are observations from the supplied dataset, not new guaranteed specifications or proof of every intermediate frequency.

| Quantity | Range or maximum in the supplied records | Source |
|---|---|---|
| Small-signal gain | 55.42–63.88 dB | S21-0.xlsx, Small Signal; see gain-flatness calculation for the point-set interpretation |
| Input VSWR | Maximum 1.789:1 at 16.7 GHz | S21-0.xlsx; quantity identified by its SWR summary and the report |
| Output P1dB | 46.90–50.92 dBm | power.xlsx, Sheet1 |
| Output P3dB | 48.92–52.05 dBm | power.xlsx, Sheet1 |
| Saturated output | 50.017–52.650 dBm | power.xlsx, Sheet1 |
The saturated-output range corresponds to approximately 100.4–184.1 W, using P_W = 10^((P_dBm − 30)/10) on the unrounded source values. It does not establish the linear output available for a specified modulated signal. Small-signal gain, compressed output and saturated output describe different operating conditions and should not be combined into an invented single operating point.
Locate the efficiency problem precisely
In power.xlsx, current ranges E3:E123, J3:J123 and O3:O123 each contain 121 stored zeros. The corresponding efficiency columns F, K and P contain 363 division-by-zero results in total. A representative formula divides RF output power by 28 times the current entry.

The constant 28 is a voltage assumption in that formula; it is not an independent voltage measurement. The zeros do not prove that an operating amplifier drew zero current, and the formula errors do not mean that efficiency was measured as zero. Preserve the RF readings while leaving the affected efficiency result unverified.
Calculate only after the inputs belong to the same operating point
Obtain measured voltage and current at the same steady electrical boundary and RF operating point before calculating input power. Use power amplifier efficiency definitions to choose drain efficiency or PAE and the included loads; the workbook’s assumed voltage cannot replace this measurement.

| Supplemental input | Matching fields required in the same record |
|---|---|
| RF input and output | Exact model/suffix, configuration, identified DUT, frequency, waveform, operating point and both planes |
| DC input | Measured voltage/current, rail or module boundary and the same state as the RF readings |
| Timing and thermal conditions | Measurement timing, duty where relevant, cooling and temperature points |
| Traceability and request | Test date, setup/instruments, source files/cells; confirm requested records against the factory testing and documentation scope |
The PDF’s issue date, 2026-08-13, is not a substitute for its missing test date or unit identity. Likewise, the separate 2–6 GHz current records cannot be substituted for this 6–18 GHz dataset. A datasheet current limit is also not a measured current at one of these RF operating points.
Publish the supported result and retain the open calculation
Describe the RF summaries within their stated point-set and identity limits, and leave numerical efficiency unverified. Preserve the original workbook; later derived calculations must identify new inputs and cells separately. The spurious test-report comparison is another open question and cannot supply missing DC measurements.
To explore current hardware in the same band, see the 6–18 GHz amplifier product family. Request data for the exact candidate and suffix; that catalog entry does not repair the missing current records or establish the identity of this test unit.
If comparing actual candidates after the dataset gap is resolved, use the aligned efficiency review for matched definitions, conditions and evidence strength. The present dataset audit does not establish the sample’s semiconductor technology or a material advantage.
Identify the 6–18 GHz amplifier configuration and the voltage, current, RF-power, or test-condition records still needed.