RF amplifier efficiency test data need matching electrical inputs as well as RF output readings at the same operating point. The supplied 6–18 GHz files show this distinction: power, small-signal gain and input VSWR records are available, but the stored current values cannot support a verified efficiency result.

Keep the measured quantities separate

The raw sweeps contain 121 frequency points from 6 to 18 GHz at 100 MHz intervals. The following values summarize those stored points. They are observations from the supplied dataset, not new guaranteed specifications or proof of every intermediate frequency.

Saved P1dB, P3dB and saturated output samples are plotted as separate series.
Quantity Range or maximum in the supplied records Source
Small-signal gain55.42–63.88 dBS21-0.xlsx, Small Signal; see gain-flatness calculation for the point-set interpretation
Input VSWR Maximum 1.789:1 at 16.7 GHz S21-0.xlsx; quantity identified by its SWR summary and the report
Output P1dB 46.90–50.92 dBm power.xlsx, Sheet1
Output P3dB 48.92–52.05 dBm power.xlsx, Sheet1
Saturated output 50.017–52.650 dBm power.xlsx, Sheet1

The saturated-output range corresponds to approximately 100.4–184.1 W, using P_W = 10^((P_dBm − 30)/10) on the unrounded source values. It does not establish the linear output available for a specified modulated signal. Small-signal gain, compressed output and saturated output describe different operating conditions and should not be combined into an invented single operating point.

Locate the efficiency problem precisely

In power.xlsx, current ranges E3:E123, J3:J123 and O3:O123 each contain 121 stored zeros. The corresponding efficiency columns F, K and P contain 363 division-by-zero results in total. A representative formula divides RF output power by 28 times the current entry.

Three current ranges contain stored zeros; the corresponding efficiency cells contain division errors.

The constant 28 is a voltage assumption in that formula; it is not an independent voltage measurement. The zeros do not prove that an operating amplifier drew zero current, and the formula errors do not mean that efficiency was measured as zero. Preserve the RF readings while leaving the affected efficiency result unverified.

Calculate only after the inputs belong to the same operating point

Obtain measured voltage and current at the same steady electrical boundary and RF operating point before calculating input power. Use power amplifier efficiency definitions to choose drain efficiency or PAE and the included loads; the workbook’s assumed voltage cannot replace this measurement.

RF and DC evidence must share the operating point and the stated electrical boundary.
Supplemental inputMatching fields required in the same record
RF input and outputExact model/suffix, configuration, identified DUT, frequency, waveform, operating point and both planes
DC inputMeasured voltage/current, rail or module boundary and the same state as the RF readings
Timing and thermal conditions Measurement timing, duty where relevant, cooling and temperature points
Traceability and requestTest date, setup/instruments, source files/cells; confirm requested records against the factory testing and documentation scope

The PDF’s issue date, 2026-08-13, is not a substitute for its missing test date or unit identity. Likewise, the separate 2–6 GHz current records cannot be substituted for this 6–18 GHz dataset. A datasheet current limit is also not a measured current at one of these RF operating points.

Publish the supported result and retain the open calculation

Describe the RF summaries within their stated point-set and identity limits, and leave numerical efficiency unverified. Preserve the original workbook; later derived calculations must identify new inputs and cells separately. The spurious test-report comparison is another open question and cannot supply missing DC measurements.

To explore current hardware in the same band, see the 6–18 GHz amplifier product family. Request data for the exact candidate and suffix; that catalog entry does not repair the missing current records or establish the identity of this test unit.

If comparing actual candidates after the dataset gap is resolved, use the aligned efficiency review for matched definitions, conditions and evidence strength. The present dataset audit does not establish the sample’s semiconductor technology or a material advantage.

Identify the 6–18 GHz amplifier configuration and the voltage, current, RF-power, or test-condition records still needed.