CorelixRF RF power amplifier testing and manufacturing environment
Factory-Direct RF Power Amplifier Manufacturer

Standard RF Power Amplifier Modules

Compare CRF-PA module options by frequency, power class and model-specific operating conditions.

Compare 20 CRF-PA RF power amplifier modules across four separate frequency families: 30–512 MHz, 300–1700 MHz, 300–2700 MHz and 2–6 GHz. Each family lists 30, 50, 100, 150 and 200 W options. Select your operating band and output requirement, then review the model’s supply, current, RF interfaces and cooling conditions.

4 Separate Frequency Families30W–200W20 Standard CRF-PA ModelsModel-Specific RF InterfacesExternal Heat-Sink Modules
CorelixRF standard RF power amplifier module
RF power amplifier test bench
RF amplifier module measurement setup
RF amplifier cooling and connector review
20Std Models
4Band Families
5Power Tiers
RFTest Data
Factory
Direct RF PA manufacturing and engineering review.
20 Models
Model-specific specifications and configuration review.
4 Families
Four separate frequency families with five power tiers.
30–200W
Power tiers for evaluation and system integration.
Data
Datasheets, typical curves and RF test records.
Buyer Problems

What to Confirm Before Selecting an RF Amplifier Module

Before selecting an RF amplifier module, confirm the full operating band, output definition, DC supply, current margin and cooling arrangement. Review the RF connections and load conditions together with the model specifications to identify a suitable configuration.

01

Need Real Manufacturer

Catalog resellers often cannot support model-level engineering questions.

Factory review
02

Hard to Shortlist

Multiple frequency bands and power levels make comparison slow.

20-model matrix
03

Voltage Risk

Confirm the exact model and version before selecting the DC supply.

VDC by model
04

Thermal Unclear

Current consumption, airflow and duty cycle must be checked early.

Cooling review
05

RF Chain Mismatch

Antenna, load VSWR, cable loss and connector choices affect PA selection.

System matching
Standard Models

Compare 20 Standard RF Power Amplifier Modules

Compare the CRF-PA models by frequency, output power, gain, supply voltage, current, RF connections and mechanical dimensions. Select an RF power amplifier module that fits both the electrical requirements and the available installation space.

Filter Matrix

Filter by frequency family, compare the model specifications, then request the selected model’s datasheet or quotation.

Model Frequency Power Gain Flatness / Input VSWR Supply Current Connector / Cooling Size / Weight CTA
CRF-PA-30M512M-30WJune 2026 V1.0 · module 30–512MHz 30 W Typ
25 W Min · Psat
36 dB Min / 46 dB Max Flatness: −4 to +4 dB
Input VSWR: ≤1.8
24 V Min / 28 V Typ / 32 V Max 3.2 A Typ / 4 A Max SMA-KFD46 input / output
External heat sink · CW
125×59×21.5 mm / 0.5 kg
CRF-PA-30M512M-50WJune 2026 V1.0 · module 30–512MHz 50 W Typ
40 W Min · Psat
38 dB Min / 48 dB Max Flatness: −4 to +4 dB
Input VSWR: ≤1.8
24 V Min / 28 V Typ / 32 V Max 7.2 A Typ / 9 A Max SMA-KFD46 input / output
External heat sink · CW
125×59×21.5 mm / 0.5 kg
CRF-PA-30M512M-100WJune 2026 V1.0 · module 30–512MHz 100 W Typ
80 W Min · Psat
41 dB Min / 51 dB Max Flatness: −4 to +4 dB
Input VSWR: ≤1.8
24 V Min / 28 V Typ / 32 V Max 14.5 A Typ / 18 A Max SMA-F input / N-F output
External heat sink · CW
160×120×25 mm / 1.4 kg
CRF-PA-30M512M-150WJune 2026 V1.0 · module 30–512MHz 150 W Typ
120 W Min · Psat
43 dB Min / 53 dB Max Flatness: −4 to +4 dB
Input VSWR: ≤1.8
24 V Min / 28 V Typ / 32 V Max 16 A Typ / 20 A Max SMA-F input / N-F output
External heat sink · CW
200×158×25 mm / 1.4 kg
CRF-PA-30M512M-200WJune 2026 V1.0 · module 30–512MHz 200 W Typ
158 W Min · Psat
44 dB Min / 54 dB Max Flatness: −4 to +4 dB
Input VSWR: ≤1.8
24 V Min / 28 V Typ / 32 V Max 29 A Typ / 36 A Max SMA-F input / N-F output
External heat sink · CW
200×158×25 mm / 1.4 kg
CRF-PA-300M1700M-30WJune 2026 V1.0 · module 300–1700MHz 30 W Typ
25 W Min · Psat
36 dB Min / 46 dB Max Flatness: −4 to +4 dB
Input VSWR: ≤1.8
24 V Min / 28 V Typ / 32 V Max 2.4 A Typ / 3 A Max SMA-KFD46 input / output
External heat sink · CW
125×59×21.5 mm / 0.5 kg
CRF-PA-300M1700M-50WJune 2026 V1.0 · module 300–1700MHz 50 W Typ
40 W Min · Psat
38 dB Min / 48 dB Max Flatness: −4 to +4 dB
Input VSWR: ≤1.8
24 V Min / 28 V Typ / 32 V Max 5.6 A Typ / 7 A Max SMA-KFD46 input / output
External heat sink · CW
125×59×21.5 mm / 0.5 kg
CRF-PA-300M1700M-100WJune 2026 V1.0 · module 300–1700MHz 100 W Typ
80 W Min · Psat
41 dB Min / 51 dB Max Flatness: −4 to +4 dB
Input VSWR: ≤1.8
24 V Min / 28 V Typ / 32 V Max 11.5 A Typ / 14 A Max SMA-F input / N-F output
External heat sink · CW
200×158×25 mm / 1.4 kg
CRF-PA-300M1700M-150WJune 2026 V1.0 · module 300–1700MHz 150 W Typ
120 W Min · Psat
43 dB Min / 53 dB Max Flatness: −4 to +4 dB
Input VSWR: ≤1.8
24 V Min / 28 V Typ / 32 V Max 18 A Typ / 22 A Max SMA-F input / N-F output
External heat sink · CW
200×158×25 mm / 1.4 kg
CRF-PA-300M1700M-200WRequest the model-specific configuration and datasheet 300–1700MHz 200 W class
Confirm output definition
Confirm with model-specific datasheet Confirm with model-specific datasheet Confirm with model-specific datasheet Confirm with model-specific datasheet Confirm with model-specific datasheet Confirm with model-specific datasheet
CRF-PA-300M2700M-30WJune 2026 V1.0 · module 300–2700MHz 30 W Typ
25 W Min · Psat
36 dB Min / 46 dB Max Flatness: −4 to +4 dB
Input VSWR: ≤1.8
24 V Min / 28 V Typ / 32 V Max 3.2 A Typ / 4 A Max SMA-KFD46 input / output
External heat sink · CW
125×59×21.5 mm / 0.5 kg
CRF-PA-300M2700M-50WJune 2026 V1.0 · module 300–2700MHz 50 W Typ
40 W Min · Psat
38 dB Min / 48 dB Max Flatness: −4 to +4 dB
Input VSWR: ≤1.8
24 V Min / 28 V Typ / 32 V Max 7.2 A Typ / 9 A Max SMA-KFD46 input / output
External heat sink · CW
125×59×21.5 mm / 0.5 kg
CRF-PA-300M2700M-100WJune 2026 V1.0 · module 300–2700MHz 100 W Typ
80 W Min · Psat
41 dB Min / 51 dB Max Flatness: −4 to +4 dB
Input VSWR: ≤1.8
24 V Min / 28 V Typ / 32 V Max 14.5 A Typ / 18 A Max SMA-F input / N-F output
External heat sink · CW
200×158×25 mm / 1.4 kg
CRF-PA-300M2700M-150WJune 2026 V1.0 · module 300–2700MHz 150 W Typ
120 W Min · Psat
43 dB Min / 53 dB Max Flatness: −4 to +4 dB
Input VSWR: ≤1.8
24 V Min / 28 V Typ / 32 V Max 16 A Typ / 20 A Max SMA-F input / N-F output
External heat sink · CW
200×158×25 mm / 1.4 kg
CRF-PA-300M2700M-200WJune 2026 V1.0 · module 300–2700MHz 200 W Typ
158 W Min · Psat
44 dB Min / 54 dB Max Flatness: −4 to +4 dB
Input VSWR: ≤1.8
24 V Min / 28 V Typ / 32 V Max 29 A Typ / 36 A Max SMA-F input / N-F output
External heat sink · CW
200×158×25 mm / 1.4 kg
CRF-PA-2000M6000M-30WJune 2026 V1.0 · module 2–6GHz 30 W Typ
25 W Min · Psat
36 dB Min / 46 dB Max Flatness: −3 to +3 dB
Input VSWR: ≤1.8
24 V Min / 28 V Typ / 32 V Max 3.2 A Typ / 4 A Max SMA-KFD46 input / output
External heat sink · CW
125×59×21.5 mm / 0.5 kg
CRF-PA-2000M6000M-50WJune 2026 V1.0 · module 2–6GHz 50 W Typ
40 W Min · Psat
40 dB Min / 58 dB Max Flatness: −3 to +3 dB
Input VSWR: ≤1.8
24 V Min / 28 V Typ / 32 V Max 10 A Typ / 12 A Max SMA-F input / N-F output
External heat sink · CW
200×158×25 mm / 1.4 kg
CRF-PA-2000M6000M-100WJune 2026 V1.0 · module 2–6GHz 100 W Typ
80 W Min · Psat
41 dB Min / 51 dB Max Flatness: −3 to +3 dB
Input VSWR: ≤1.8
24 V Min / 28 V Typ / 32 V Max 19 A Typ / 24 A Max SMA-F input / N-F output
External heat sink · CW
200×158×25 mm / 1.4 kg
CRF-PA-2000M6000M-150WJune 2026 V1.0 · module 2–6GHz 150 W Typ
120 W Min · Psat
43 dB Min / 58 dB Max Flatness: −3 to +3 dB
Input VSWR: ≤1.8
24 V Min / 28 V Typ / 32 V Max 22 A Typ / 27 A Max SMA-F input / N-F output
External heat sink · CW
200×158×25 mm / 1.4 kg
CRF-PA-2000M6000M-200WJune 2026 V1.0 · module version 2–6GHz 200 W Typ
160 W Min · Psat
44 dB Min / 54 dB Max Flatness: −3 to +3 dB
Input VSWR: ≤1.8
24 V Min / 28 V Typ / 32 V Max 29 A Typ / 36 A Max SMA-F input / N-F output
External heat sink · CW
200×158×25 mm / 1.4 kg

Note: The documented module rows use June 2026 V1.0 datasheets: 50 Ω, nominal +28 V DC, normal-temperature CW conditions. Read minimum, typical and maximum values separately. Output is Psat, not guaranteed linear modulated power. RF interfaces, dimensions and current are model-specific, and an external heat sink is required. Confirm the 300–1700 MHz 200 W configuration from its model-specific datasheet before selection. The 2–6 GHz 200 W module and AC-powered rack are different configurations.

Frequency Families

Choose an RF Amplifier Module by Frequency

These four frequency families are separate RF amplifier module options. Match your full operating band to the relevant family, then compare its 30, 50, 100, 150 and 200 W models. Confirm the selected model’s supply and performance conditions before integration.

30–512MHz

Lower-Band RF PA Platforms

28VDC models for lower-band RF testing, communication and integration projects.

30W / 50W / 100W / 150W / 200W View 30–512 MHz Modules →
300–1700MHz

Wideband Mid-Band Platforms

28VDC platforms for broad RF test and integration coverage across 300–1700MHz.

5 power tiers View 300–1700 MHz Modules →
300–2700MHz

Extended Broadband Platforms

Compare each model’s output, current, RF interfaces and external cooling requirements.

Model-specific requirements View 300–2700 MHz Modules →
2–6GHz

High-Frequency Broadband PA

Documented 2–6GHz modules use 24–32 VDC with 28 V nominal; verify the ordered configuration.

24–32 VDC modules View 2–6 GHz Modules →
Power Selection

Select Output Power by System Requirement

Compare output power together with frequency coverage, operating mode, supply voltage and current. The listed power ratings must be read under their specified conditions. For linear operation, provide the signal bandwidth and distortion requirements so the suitable output level can be reviewed. The engineering guide A Practical Guide to RF Power Amplifier Specifications develops the selection and interface questions in more detail.

30W

Compact Evaluation

For lower output requirements, compact test setups and early-stage system evaluation.

50W

Moderate RF Output

Common for evaluation systems and moderate power integration where current margin matters.

100W

Common High-Power Tier

A frequent starting point for high-power RF test and communication integration projects.

150W

Higher Output Review

Requires careful review of current, airflow, load condition and duty cycle.

200W

Highest Standard Tier

Needs stronger thermal review, supply margin and antenna / load VSWR confirmation.

Factory Evidence

Model-Level RF Testing and Documentation

Review the datasheet and available RF test data for the selected module, including frequency response, output power, gain and applicable matching or protection checks. Agree the signal, supply, cooling and load conditions, together with the documentation required for your order. Before preparing the enquiry, use Buying a 100 W RF Amplifier: Check Output Before You Order to organize the decision inputs.

RF amplifier output power testing with measurement equipment
RF amplifier module connected with coaxial cables
RF test data and engineering documentation review
CorelixRF RF amplifier workshop and validation support
01

Output Power Verification

Model-level output power can be reviewed with measured data and test references.

02

Gain / Flatness Review

Gain reference and frequency response data help buyers compare standard models.

03

VSWR / Protection Check

Load condition and input / output matching should be checked before integration.

04

Datasheet / OEM Docs

Datasheets, test reports, packing files and OEM documentation can be prepared by project scope.

Integration Review

Integrate an RF PA Module into Your System

Before integrating an RF PA module, check the input drive, DC supply, current margin, RF connections, mounting space and cooling path. For a broadband RF power amplifier module, review these requirements across the intended operating band.

When selecting a solid-state power amplifier for integration, confirm that the selected solid-state RF amplifier configuration fits the available enclosure, control connections and load conditions.

Air Cooling

Cooling Condition

Confirm airflow, heat path and installation environment before system assembly.

Current Margin

Power Supply Review

Current consumption changes by frequency family and power tier, especially 2–6GHz.

Mechanical Fit

Size and Mounting

30W/50W models may use compact format; higher power models typically need larger module space.

RF Chain

Load VSWR / Antenna Match

Amplifier output should be reviewed with cable loss, antenna power handling and load condition.

Applications

Applications for Standard RF Amplifier Modules

Compare standard RF amplifier modules for laboratory testing, communications, SDR signal chains and OEM subsystem integration. Select the model against the actual frequency, signal, output and load requirements of your application.

01

RF Test & Laboratory

Amplifier platforms for test benches, measurement setups and validation chains.

02

SDR Signal Chain

Boost RF output from SDR or signal source modules into higher-power RF chains.

03

Subsystem Integration

Standard PA modules can serve as starting points for OEM hardware platforms.

04

UAV / Telemetry RF

Engineering-side RF amplifier support for controlled telemetry and link platforms.

05

C-UAS / EW Support

RF hardware integration support for specialized engineering and validation systems.

FAQ

RF Amplifier Module Selection FAQ

Review the model, supply, documentation and integration requirements before requesting a quotation.

The catalog lists 20 CRF-PA models across four separate frequency families: 30–512 MHz, 300–1700 MHz, 300–2700 MHz and 2–6 GHz. Each family includes 30, 50, 100, 150 and 200 W options.

The 30–512 MHz, 300–1700 MHz and 300–2700 MHz families list 28 VDC supplies. The 2–6 GHz models use model-specific supply ranges. Check the exact model row and datasheet before selecting a power supply.

Request the datasheet for your selected model and specify the measurements you need. Available performance curves, RF test records and documentation depend on the model and agreed order scope.

Share the required changes to frequency, output, supply, RF connections, control interface or mechanical format. CorelixRF can review the suitability of a standard platform and the scope of any custom configuration.

Send the model reference, operating band, required output, signal conditions and quantity. Include supply, cooling, RF interfaces, load conditions and any required test data or documentation.

Include the device-technology requirement with your operating band, output target and model reference. Confirm the selected configuration against its datasheet and measured performance, including gain, linearity and thermal conditions.

Engineering Review

Request an RF Power Amplifier Module Quote

Send your preferred CRF-PA model or required frequency band and output power. Include the signal conditions, DC supply, cooling arrangement, RF interfaces and quantity so our team can review a suitable standard module or custom configuration.