To investigate intermodulation distortion (IMD) in an RF power amplifier two-tone test, start with two records: the signal delivered to the amplifier input and the response of the receiving chain. An IM3 reading alone cannot tell an RF test engineer which part of the setup contributed distortion. Check the source path and the analyzer before deciding how much the measurement says about the device under test (DUT).

The practical question is whether the next check belongs on the amplifier or elsewhere on the bench. Keep the operating conditions beside each result, record every path change, and leave the attribution unresolved when the comparison is not controlled.

Define intermodulation distortion and two-tone power

Write down f1 and f2 first. For nearby tones with f1 below f2, locate the near-carrier IM3 products at 2f1−f2 and 2f2−f1, using one frequency unit throughout. Give the lower and upper products separate entries in the record. If a result is relative to a carrier, identify that carrier beside the value. The next evidence review is developed in RF Sidebands Near a Carrier: Separate the Signal from the Test Setup; retain the relevant setup and acceptance conditions when using it.

Keep the power definitions beside the readings:

QuantityWhat to record
Each fundamental toneIts average power and frequency, at a stated reference plane
Two-tone average totalThe sum of the two fundamental powers in W or mW; exclude distortion products and noise from this definition
Each IM3 productIts frequency, absolute level and reference carrier for a dBc result
Reference planeDUT input, DUT output or analyzer input, with the applicable path-loss correction

Average over enough time to account for the two-tone beat variation. The total defined here is average power, not peak envelope power. Two equal-power tones have a combined average level about 3.01 dB above either tone. For unequal tones, convert the dBm values to linear power, add those powers, then convert back; do not add the dBm readings directly.

Keep the unit and sign with every level: dBm is power relative to 1 mW, while dB describes a ratio. For a signed IM3 value in dBc, subtract the specified carrier level from the product level. A positive carrier-to-product separation uses a different sign convention; reconcile it before comparing reports.

In RF amplifier testing, an instrument's “Average Tone Power” may mean the arithmetic average of two dBm readings. Check the instrument definition before using that field as a total. Also distinguish generator settings from measured power at the DUT input. The broader RF amplifier measurement conditions guide covers the records needed across other amplifier tests.

Reference-based generated illustration of the amplifier input, control and supply side.

Check the RF signal generator and combining path

Start with the RF signal generator and combining path. Check source-to-source leakage, combiner isolation, harmonics, spurious signals near the frequencies of interest and automatic level control (ALC) settings. Use a suitable load and a receiving path whose own limitations have been assessed when examining the signal at the DUT input plane.

Changing a combiner, adding isolation or inserting a filter changes the path. Recheck the actual input power of each tone before comparing IM3 results. A lower reading after a path change needs to be considered alongside any change in DUT drive or loading.

Bypassing the amplifier is not a complete attribution test on its own. It can also change the receiver level and the load presented to the source path. Record those differences rather than treating the bypass trace as an automatically comparable baseline.

Choose isolation, filtering and ALC settings for the actual equipment and signal path. A blanket instruction to disable ALC, or a single isolation target for every bench, does not establish a clean source. Record the settings and check the signal that reaches the DUT after each change.

Check spectrum analyzer distortion with comparable DUT conditions

The spectrum analyzer can contribute intermodulation distortion. Examine its response to changes in receive level or attenuation while keeping the DUT's actual input drive, load, supply and thermal state comparable.

Record internal and external attenuation separately, together with preamplifier state, reference level, resolution and video bandwidth, and relevant IF or automatically coupled settings. Correct the carrier and IM3 readings to the same reference plane using the applicable frequency-dependent path losses.

External attenuation can affect matching as well as level. Unchanged front-panel settings do not establish that the DUT sees unchanged conditions. Include the effect of any added output-path components in the comparison.

Before interpreting an attenuation check, identify whether noise, overload or the analyzer architecture limits the reading. An IM3 product below the measurement noise floor has not been shown to disappear. A chosen attenuation step also does not guarantee a fixed improvement. Keep those limits with the observation instead of turning an instrument-specific response into a universal rule.

The source check depends on the receiving chain, and the receiver check depends on a comparable source signal. Revisit either check if the other exposes a limitation.

Reference-based generated illustration of an amplifier RF output connector and nearby cable.

Decide what the evidence supports

Separate the observation from its interpretation. A change in IM3 after one adjustment does not, by itself, identify the component responsible. Use the two checks together and retain an unresolved result when the conditions do not support a stronger conclusion.

Evidence in the recordNext actionLimit on the conclusion
Source contribution remains unresolvedRecheck the combined signal at the DUT input and the receiver used for that checkDo not assign the full result to the amplifier
Receiver noise, overload or self-generated IMD limits the comparisonReview analyzer settings and the output path; repeat with comparable DUT conditionsThe current reading does not isolate DUT distortion
Drive, load, supply or thermal conditions changedRe-establish comparable conditions and document the differencesDo not treat the readings as a controlled comparison
Both setup checks are documented and DUT-related evidence remainsContinue DUT evaluation at the recorded operating point, keeping unresolved contributions visibleThis still does not prove the DUT is the sole source
The available records cannot distinguish the contributionsState “not determined” and identify the next checkDo not calculate an unmeasured contribution or cancellation

Keep drive power and compression limits with the operating-point record. Two-tone results apply to the frequencies, spacing, levels and conditions measured; they do not establish compliance for every modulated waveform.

If a report includes IP3, keep it separate from measured output capability. IP3 is an extrapolated intercept under applicable weakly nonlinear conditions. State whether it is input-referred IIP3 or output-referred OIP3, and use the corresponding per-tone quantities rather than total power. Check source and receiver contributions, noise and compression before relying on the extrapolation; the intercept is not an output power the amplifier can necessarily deliver.

Prepare a record for the candidate amplifier

For a candidate such as the CRF-PA-300M1700M-100W, use the applicable datasheet as the starting point for a test-preparation record. Match the document to the intended hardware version and ordered configuration before comparing results.

Check the proposed frequencies and spacing, per-tone and total-power definitions, input and output reference planes, permitted drive conditions, supply, cooling and controls. Identify which test records would be comparable at those conditions. This preparation checklist does not establish that the candidate has passed the intended two-tone test.

Confirm configuration details from the applicable documentation. Optional controls should remain optional in the record, and cooling or interface details should not be inferred from an illustration. For model selection and installation questions, use the existing CRF-PA-300M1700M-100W integration guide.

Reference-based generated illustration of an amplifier module with an external heat sink.

Send a report another engineer can compare

For RF power amplifier testing, attach the conditions to the result when discussing a candidate with a supplier. The following fields keep the source and receiver checks available to the person reviewing the amplifier:

RecordInclude
HardwareModel, revision and intended configuration
Signal and powerf1, f2, spacing, each tone's average level, total-power definition and reference planes
Source checkSource and combining-path configuration, relevant settings, input observations and changes made
Receiver checkAttenuation, reference level, preamplifier and bandwidth settings, path corrections and observed limitations
DUT conditionsSupply, load, cooling, thermal state and control configuration during the comparison
Result and next checkLower and upper IM3, reference carriers, available traces, unresolved contributions and the next evidence needed

Mark an unmeasured or unconfirmed field as unknown. Do not substitute zero. Ask whether the supplier's records use comparable conditions before comparing headline IMD or IP3 figures.