CORELIXRF · FACTORY-DIRECT RF AMPLIFIERS

Millimeter-Wave
Power Amplifier
Manufacturer

Frequency-specific platforms. Coaxial and waveguide interfaces. Built around your RF system.

CorelixRF supplies microwave and mmWave amplifier configurations for RF testing, communication links and OEM integration—with engineering, assembly and test support.

Compact & rack formatsConfiguration-specific dataOEM project support
W-BAND PLATFORM75–110 GHz
CorelixRF 75–110 GHz compact amplifier appearance from its datasheet
Waveguide interfaces. Compact integration.CRF-PA-75G110G-1W · WR10 input / output
Datasheet appearance reference

SERIES CHARACTERISTICS

A platform for each RF requirement.

Choose the operating window and hardware interface that fit your system. Electrical and mechanical details follow the selected configuration.

02

Defined output conditions

Compare rated, saturated, linear or pulsed output with its stated Min / Typ value and operating condition.

04

Integration options

Review compact or rack formats, control interfaces, power supply, air cooling and model-specific water cooling.

CorelixRF amplifier platform overview showing compact units and rack systems
CONFIGURATION OVERVIEWCompact modules to rack systems.

Compare documented frequency and output combinations. Request the matching datasheet and mechanical drawing for your configuration.

REPRESENTATIVE CONFIGURATIONS

Find your mmWave amplifier.

Start with these six configurations, or browse the full reference list below. Each frequency window belongs to a separate configuration.

Compact coaxial platform — datasheet imageDatasheet image
Compact coaxial platform

18–46 GHz

CRF-PA-18G46G-5W

Rated output
Typ 5 W
RF input
2.4 mm-F
RF output
2.4 mm-F
Coaxial to waveguide — enclosure illustrationEnclosure illustration
Coaxial to waveguide

36–50 GHz

CRF-PA-36G50G-30W

Rated output
Min 30 W
RF input
1.85 mm-F
RF output
WR22
High-output configuration — enclosure illustrationEnclosure illustration
High-output configuration

40–54 GHz

CRF-PA-40G54G-200W

Rated output
Min 200 W
RF input
1.85 mm-F
RF output
WR19
Compact broadband platform — edited enclosure referenceEdited enclosure reference
Compact broadband platform

40–67 GHz

CRF-PA-40G67G-2W

Rated output
Min 2 W
RF input
1.85 mm-F
RF output
1.85 mm-F
Waveguide RF platform — enclosure illustrationEnclosure illustration
Waveguide RF platform

50–75 GHz

CRF-PA-50G75G-5W

Rated output
Min 5 W
RF input
WR15
RF output
WR15
W-band waveguide platform — datasheet imageDatasheet image
W-band waveguide platform

75–110 GHz

CRF-PA-75G110G-1W

Rated output
Typ 1 W
RF input
WR10
RF output
WR10

Min / Typ retain their datasheet definitions. Product photos and labelled enclosure illustrations show appearance references; the matching drawing defines the final mechanical configuration.

SIDE-BY-SIDE CONFIGURATION COMPARISON

Compare mmWave Power Amplifier Configurations

Browse all 62 configurations ↓

Compare the six representative configurations by frequency, stated output and RF interface. Request the matching datasheet to review the configuration for your design or quotation.

Reference / FrequencyOutput DefinitionRF InterfacesReview NoteNext Step
CRF-PA-18G46G-5W18–46 GHzTyp 5 W Rated Output PowerInput: 2.4 mm-F / Output: 2.4 mm-FGaN technology; air cooling. Request the matching datasheet for the selected configuration.Enquire
CRF-PA-36G50G-30W36–50 GHzMin 30 W Rated Output PowerInput: 1.85 mm-F / Output: WR22Confirm operating mode, mechanical details and final configuration.Enquire
CRF-PA-40G54G-200W40–54 GHzMin 200 W Rated Output PowerInput: 1.85 mm-F / Output: WR19Confirm operating mode, mechanical details and final configuration.Enquire
CRF-PA-40G67G-2W40–67 GHzMin 2 W Rated Output PowerInput: 1.85 mm-F / Output: 1.85 mm-FConfirm operating mode, mechanical details and final configuration.Enquire
CRF-PA-50G75G-5W50–75 GHzMin 5 W Rated Output PowerInput: WR15 / Output: WR15Confirm operating mode, mechanical details and final configuration.Enquire
CRF-PA-75G110G-1W75–110 GHzTyp 1 W Rated Output PowerInput: WR10 / Output: WR10Confirm operating mode, mechanical details and final configuration.Enquire

Min / Typ and Rated Output Power retain the original definitions. Confirm CW or pulse operation, cooling and mechanical details in the matching configuration datasheet.

COMPLETE CONFIGURATION DIRECTORYExplore all 62 configurations14 frequency groups · model and specification search

62 configurations

CRF-PA-18G46G-5W

18–46 GHz
Output definitionTyp 5 W
RF interfacesInput: 2.4 mm-F / Output: 2.4 mm-F
Enquire
Configuration notes

GaN technology; air cooling. Request the matching datasheet for the selected configuration.

CRF-PA-36G50G-3W

36–50 GHz
Output definitionMin 3 W
RF interfacesInput: 2.4 mm-F / Output: 2.4 mm-F
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-36G50G-5W

36–50 GHz
Output definitionMin 5 W
RF interfacesInput: 2.4 mm-F / Output: 2.4 mm-F
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-36G50G-10W

36–50 GHz
Output definitionMin 10 W
RF interfacesInput: 1.85 mm-F / Output: WR22
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-36G50G-20W

36–50 GHz
Output definitionMin 20 W
RF interfacesInput: 1.85 mm-F / Output: WR22
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-36G50G-30W

36–50 GHz
Output definitionMin 30 W
RF interfacesInput: 1.85 mm-F / Output: WR22
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-40G54G-6W

40–54 GHz
Output definitionMin 6 W
RF interfacesInput: 1.85 mm-F / Output: WR19
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-40G54G-10W

40–54 GHz
Output definitionMin 10 W
RF interfacesInput: 1.85 mm-F / Output: WR19
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-40G54G-20W

40–54 GHz
Output definitionMin 20 W
RF interfacesInput: 1.85 mm-F / Output: WR19
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-40G54G-40W

40–54 GHz
Output definitionTyp 40 W
RF interfacesInput: 1.85 mm-F / Output: WR19
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-40G54G-80W

Standard Version40–54 GHz
Output definitionMin 80 W
RF interfacesInput: 1.85 mm-F / Output: WR-19
Enquire
Configuration notes

Gain Min 50 dB; gain flatness Max ±10 dB; RS485 / LAN control; air cooling.

CRF-PA-40G54G-80W

H-Version40–54 GHz
Output definitionMin 80 W
RF interfacesInput: 1.85 mm-F / Output: WR-19
Enquire
Configuration notes

Gain Min 49 dB; gain flatness Max ±2 dB; P1dB output Min 50 W; RS485 / LAN control; air cooling.

CRF-PA-40G54G-120W

40–54 GHz
Output definitionMin 120 W
RF interfacesInput: 1.85 mm-F / Output: WR19
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-40G54G-200W

40–54 GHz
Output definitionMin 200 W
RF interfacesInput: 1.85 mm-F / Output: WR19
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-40G67G-1W

Gain Min 27 dB configuration40–67 GHz
Output definitionMin 1 W
RF interfacesInput: 1.85 mm-F / Output: 1.85 mm-F
Enquire
Configuration notes

Gain Min 27 dB; gain flatness Max ±8 dB; RS485 control; air cooling.

CRF-PA-40G67G-1W

Gain Min 26 dB configuration40–67 GHz
Output definitionMin 1 W
RF interfacesInput: 1.85 mm-F / Output: 1.85 mm-F
Enquire
Configuration notes

Gain Min 26 dB; gain flatness Max ±10 dB; noise floor Typ −40 dBm/MHz; RS485 / LAN control; air cooling. For a configuration-specific engineering example, see 65–75 GHz V-Band mmWave Power Amplifier Selection Guide.

CRF-PA-40G67G-2W

40–67 GHz
Output definitionMin 2 W
RF interfacesInput: 1.85 mm-F / Output: 1.85 mm-F
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-40G67G-5W

40–67 GHz
Output definitionMin 5 W
RF interfacesInput: 1.85 mm-F / Output: 1.85 mm-F
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-47G51.4G-50W

47–51.4 GHz
Output definitionMin 50 W
RF interfacesInput: 1.85 mm-F / Output: WR19
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-47G51.4G-200W

47.2–51.4 GHz
Output definitionMin 53 dBm
RF interfacesInput: WR19 / 1.85 mm-K / Output: WR19
Enquire
Configuration notes

Use the documented 47.2–51.4 GHz range and Min 53 dBm output. The 200 W model name is a reference label. DC and AC enclosure dimensions differ; select the supply configuration first.

CRF-PA-47G51.4G-400W

47–51.4 GHz
Output definitionSaturated: Min 400 W (56 dBm); Linear/rated: Min 100 W (50 dBm)
RF interfacesInput: 1.85 mm-F / Output: WR19
Enquire
Configuration notes

Saturated output: Min 400 W. Linear output: Min 100 W. Select the output condition for your application.

CRF-PA-50G65G-6W

50–65 GHz
Output definitionMin 6 W
RF interfacesInput: 1.85 mm-F / Output: WR15
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-50G65G-10W

50–65 GHz
Output definitionMin 10 W
RF interfacesInput: 1.85 mm-F / Output: WR15
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-50G65G-20W

50–65 GHz
Output definitionMin 20 W
RF interfacesInput: 1.85 mm-F / Output: WR15
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-50G65G-40W

50–65 GHz
Output definitionMin 40 W
RF interfacesInput: 1.85 mm-F / Output: WR15
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-50G65G-80W

50–65 GHz
Output definitionMin 80 W
RF interfacesInput: 1.85 mm-F / Output: WR15
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-50G65G-120W

50–65 GHz
Output definitionMin 120 W
RF interfacesInput: 1.85 mm-F / Output: WR15
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-50G65G-500W

50–65 GHz
Output definitionMin 500 W pulse / Min 250 W CW
RF interfacesInput: 1.85 mm-F / Output: WR15
Enquire
Configuration notes

Water Cooling; AC 380 V ±10%, 50/60 Hz. Min 500 W pulse / Min 250 W CW. Operating conditions follow the project-approved datasheet.

CRF-PA-50G67G-3W

50–67 GHz
Output definitionMin 3 W
RF interfacesInput: 1.85 mm-F / Output: 1.85 mm-F
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-50G67G-6W

50–67 GHz
Output definitionMin 6 W
RF interfacesInput: 1.85 mm-F / Output: WR15
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-50G67G-10W

50–67 GHz
Output definitionMin 10 W
RF interfacesInput: 1.85 mm-F / Output: WR15
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-50G67G-16W

50–67 GHz
Output definitionMin 16 W
RF interfacesInput: 1.85 mm-F / Output: WR15
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-50G75G-2W

50–75 GHz
Output definitionMin 2 W
RF interfacesInput: 1.85 mm-F / Output: WR15
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-50G75G-3W

50–75 GHz
Output definitionMin 3 W
RF interfacesInput: WR15 / Output: WR15
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-50G75G-5W

50–75 GHz
Output definitionMin 5 W
RF interfacesInput: WR15 / Output: WR15
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-50G75G-8W

50–75 GHz
Output definitionMin 8 W
RF interfacesInput: WR15 / Output: WR15
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-65G75G-4W

65–75 GHz
Output definitionMin 4 W
RF interfacesInput: WR15 / Output: WR15
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-65G75G-8W

65–75 GHz
Output definitionMin 8 W
RF interfacesInput: WR15 / Output: WR15
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-65G75G-12W

65–75 GHz
Output definitionMin 12 W
RF interfacesInput: WR15 / Output: WR15
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-65G75G-20W

65–75 GHz
Output definitionMin 20 W
RF interfacesInput: WR15 / Output: WR15
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-65G75G-35W

65–75 GHz
Output definitionMin 35 W
RF interfacesInput: WR15 / Output: WR15
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-75G110G-1W

75–110 GHz
Output definitionTyp 1 W
RF interfacesInput: WR10 / Output: WR10
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-75G110G-2W

75–110 GHz
Output definitionTyp 2 W
RF interfacesInput: WR10 / Output: WR10
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-75G110G-3W

75–110 GHz
Output definitionMin 3 W
RF interfacesInput: WR10 / Output: WR10
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-75G110G-4W

75–110 GHz
Output definitionTyp 4 W
RF interfacesInput: WR10 / Output: WR10
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-75G81G-2W

75–81 GHz
Output definitionMin 2 W
RF interfacesInput: WR10 / Output: WR10
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-75G81G-6W

75–81 GHz
Output definitionMin 6 W
RF interfacesInput: WR10 / Output: WR10
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-75G81G-10W

75–81 GHz
Output definitionMin 10 W
RF interfacesInput: WR10 / Output: WR10
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-75G81G-16W

75–81 GHz
Output definitionMin 16 W
RF interfacesInput: WR10 / Output: WR10
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-75G81G-30W

75–81 GHz
Output definitionMin 30 W
RF interfacesInput: WR10 / Output: WR10
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-81G86G-2W

81–86 GHz
Output definitionMin 2 W
RF interfacesInput: WR10 / Output: WR10
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-81G86G-6W

81–86 GHz
Output definitionMin 6 W
RF interfacesInput: WR10 / Output: WR10
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-81G86G-10W

81–86 GHz
Output definitionMin 10 W
RF interfacesInput: WR10 / Output: WR10
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-81G86G-16W

81–86 GHz
Output definitionMin 16 W
RF interfacesInput: WR10 / Output: WR10
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-81G86G-30W

81–86 GHz
Output definitionMin 30 W
RF interfacesInput: WR10 / Output: WR10
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-90G98G-2W

90–98 GHz
Output definitionMin 2 W
RF interfacesInput: WR10 / Output: WR10
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-90G98G-10W

90–98 GHz
Output definitionMin 10 W
RF interfacesInput: WR10 / Output: WR10
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-92G96G-2W

92–96 GHz
Output definitionMin 2 W
RF interfacesInput: WR10 / Output: WR10
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-92G96G-6W

92–96 GHz
Output definitionMin 6 W
RF interfacesInput: WR10 / Output: WR10
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-92G96G-10W

92–96 GHz
Output definitionMin 10 W
RF interfacesInput: WR10 / Output: WR10
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-92G96G-16W

92–96 GHz
Output definitionMin 16 W
RF interfacesInput: WR10 / Output: WR10
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

CRF-PA-92G96G-30W

92–96 GHz
Output definitionMin 30 W
RF interfacesInput: WR10 / Output: WR10
Enquire
Configuration notes

Review operating mode, mechanical drawing and final supply configuration.

Output values are the electrical table’s Rated Output Power unless a different definition is shown. No CW or pulse capability is inferred from a model name. Final specifications follow the project-approved datasheet.

CorelixRF engineer reviewing a mechanical design in CAD
ENGINEERING DESIGN · CORELIXRF ASSET LIBRARY

CUSTOM CONFIGURATION & OEM SUPPORT

Fit the amplifier
to your system.

When a reference does not match your operating window or installation, our team can review the configuration with you.

Frequency & signalOperating window, bandwidth and waveform
Output & modeOutput definition, CW or pulse conditions
RF & mechanical interfacesConnectors, waveguide, mounting and space
Supply, cooling & controlPower, thermal arrangement and monitoring
Discuss your configuration

APPLICATION DIRECTIONS

Built into the RF chain.

Use the application to define the required signal, output and integration conditions for your selected configuration.

RF test & measurement

Component characterization and laboratory RF benches requiring a defined operating window, input drive and measurement plan.

Discuss a test setup ↗

Communication link testing

RF chain evaluation with signal bandwidth, modulation, linear output and back-off requirements matched to the project.

Discuss a link requirement ↗

OEM subsystem integration

Equipment integration around the RF path, supply, cooling, mounting space, control protocol and acceptance requirements.

Discuss an OEM project ↗

ENGINEERING & MANUFACTURING SUPPORT

See the work behind the hardware.

Mechanical design, module assembly and RF bench review support the path from configuration discussion to production.

Technician assembling an RF module in a metal enclosure
01 / ASSEMBLY

Module-level workmanship

Enclosure, RF connections and assembly details.

Technician reviewing RF measurements at a factory workbench
02 / RF MEASUREMENT

Bench-level validation

Agree the measurements and acceptance limits for your configuration.

RF engineer working with laboratory measurement instruments
03 / ENGINEERING SUPPORT

Project-specific documentation

Request the matching datasheet, drawing and available test records.

QUESTIONS BEFORE YOU SELECT

Clarify the details.

Keep the configuration, operating conditions and integration documents aligned.

How do I choose a millimeter wave power amplifier?

Start with the full operating window, signal bandwidth and required output definition. Then review input drive, RF interfaces, operating mode, supply and cooling against the selected reference. Use the project-approved datasheet and mechanical drawing for integration. For a configuration-specific engineering example, see 75–110 GHz W-Band Amplifiers: Comparing the 1 W to 4 W Configurations.

Which mmWave frequency ranges can be reviewed?

The references include separate 18–46, 36–50, 40–54, 40–67, 50–65, 50–67, 50–75, 65–75, 75–110, 75–81, 81–86, 90–98 and 92–96 GHz configurations, plus 47–51.4 GHz references. The 200 W-labelled reference in that last group is documented at 47.2–51.4 GHz. Each range belongs to its own configuration and is reviewed individually.

How does a mmWave amplifier relate to a microwave amplifier?

Microwave and mmWave product ranges can overlap in supplier catalogs. Select by the exact operating window and documented configuration. The CorelixRF microwave amplifier page covers broader microwave selection; this page focuses on the listed higher-frequency references, RF interfaces and integration conditions. The engineering guide Coaxial vs Waveguide Interfaces for Microwave and mmWave Amplifiers develops the selection and interface questions in more detail.

Can a broadband amplifier provide the same power across its full band?

Use the selected datasheet and frequency-dependent test information to determine output across the requested band. A broadband RF amplifier range label does not establish identical output, gain or linearity at every frequency. Retain Min and Typ definitions and the stated test conditions.

What is the difference between rated, saturated and linear output power?

These labels describe different output conditions and must be read as defined in the selected datasheet. For example, the 47–51.4 GHz / 400 W reference electrical table lists saturated output Min 400 W and linear output Min 100 W. Select the output condition that matches your application. For a configuration-specific engineering example, see Evaluating a 47–51.4 GHz 200 W Amplifier for a V-Band Test System.

Are GaN RF power amplifier configurations available?

The 18–46 GHz / 5 W and the five 36–50 GHz reference documents explicitly identify GaN technology. These support a GaN RF power amplifier configuration review. The technology of other references must be confirmed individually; this is not an all-GaN claim for the page.

START WITH YOUR OPERATING REQUIREMENT

Bring us your frequency.
Let’s define the configuration.

Share the output condition, RF interface, supply, cooling and installation needs.